Installing Management Modules - IMC Networks iMediaChassis/3 Operation Manual

Modular chassis platform
Hide thumbs Also See for iMediaChassis/3:
Table of Contents

Advertisement

Installing Management Modules

Slot 1
Management Slot
An SNMP Management Module must be installed in the iMediaChassis/3 to enable
module and chassis management (except when using modules with built-in
management, such as the iMcV-Giga-FiberLinX-II). The SNMP Management module
installs in the management slot located at the bottom left of the chassis. This slot is
only for the management module; do not install application modules such as media
conversion and mode conversion modules in this slot. Double wide modules
installed in Slot 1 will overlap the management slot.
SNMP Management Module LEDs
Each SNMP Management Module features several LEDs.
The LED functions are:
LNK/ACT
Glows green when a link is established on port.
Blinks green when data activity occurs.
FDX/COL:
Glows amber when port is in Full-Duplex mode.
Blinks amber when port is operating in Half-Duplex mode and
collisions occur.
TEMP:
Glows amber when temperature of unit surpasses a user-defined
level.
PS
Not used for the iMediaChassis/3.
FAN A / FAN B
Not used for the iMediaChassis/3.