Internal Usb Connector - HP ProLiant DL320 Generation 4 Maintenance And Service Manual

Table of Contents

Advertisement

System LED and Color
DIMM failure, all slots
in one bank (amber)
Overtemperature
(amber)
Riser interlock (amber)
Fan module (amber)
Fan module (red)
Power supply signal
interlock (amber)

Internal USB connector

For more information, refer to "Internal USB functionality (on page 52)."
Internal Health
Status
LED Color
Amber
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
DIMM in slot X is an unsupported type, but valid
memory exists in another bank.
Red
No valid or usable memory is installed in the system.
Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Red
The PCI riser board assembly is not seated.
Amber
A redundant fan has failed.
The minimum fan requirements are not being met in one or
Red
more of the fan modules. One or more fans have failed or
are missing.
The power supply signal cable is not connected to the
Red
system board.
Component identification 61