Troubleshooting
The System e-buzzer
Number of
Beeps
1
2
3
4
5
6
7
4–2
Component
Processor
Processor absent or not correctly connected. Reseat or replace
processor.
Power supply
Power supply failure. Replace power supply.
Memory
No memory, bad memory modules or incompatible memory
module. Check memory module loading order. Reseat or
replace memory modules.
Graphics card Graphics card problem. Reseat or replace the graphics card.
PCI card
PCI card problem. Reseat or replace the PCI card.
Critical system
Contact support.
failure
System Fault caused by hardware failure or software fault.
Two minutes has elapsed after the BMC starts system power
and no BOOT_START event is logged in the SEL. Possible
problems include:
System board
Defective system board. Contact support.
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Description
Clock is bad
System board problem
CPU connection to the board bad
CPU power pod failure
CPU failure
Corrupt Firmware (bad code, or improper update)