Mobile Home Installation; Methods To Maintain Ventilation - Regency F2400M Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

Once you have properly marked the position of
your unit and the floor protection as outlined in
the Residential Installation items #1 through #8,
a supply of fresh air has to be supplied to your
unit. Cut a minimum 4 inch diameter hole through
your floor protector and the floor directly under
your pedestal base to the outside. Use 4" duct
pipe with a mesh grill to pipe fresh air into the
pedestal area. Block off the hole in the back of
the pedestal with the square plate and the two
1/2" screws provided.
Place your unit in position and secure it to the
floor using two lag bolts 3/8" x 3-1/2" through
the two holes inside the pedestal base. It is
important to maintain the structural integrity of
the Mobile Home floor, walls and roof when
installing your unit.
For Mobile Home units installed in the U.S. the
unit must be grounded using a #8 ground wire
with approved termination and star washer.
CAUTION:
At no time use unlabelled
parts, or substitute parts made for
another chimney system.
Install as per chimney manufacturer's
installation instructions.
WARNING: Operate only with door fully
closed - open feed door to feed fire
only.
Regency Freestanding Woodstove

MOBILE HOME INSTALLATION

INSTALLATION
In addition to standard installation instructions
the following requirements are mandatory for
installation in a mobile home.
1) The stove must be permanently bolted to the
floor of the Mobile Home using the floor screws
provided.
2) The stove must have a permanent outside air
source for combustion.
3) The stove must be electrically grounded to
the steel chassis of the Mobile Home.
4) A listed double-wall connector chimney sys-
tem, roof thimble, spark arrestor and roof flash-
ing kit suitable for use in Mobile Homes must be
used.
5) If the chimney exits the Mobile Home at a
location other than through the roof, and exits
at a point 7ft. (2130mm) or less above the
ground level on which the Mobile Home is
positioned a guard or method of enclosing the
chimney shall be fitted at the point of exit for a
height up to 7ft. (2130mm).
6) The chimney shall be attached directly to the
room heater and shall extend at least 3 ft.
(914mm) above the part of the roof through
which it passes. The top of the chimney should
project at least 2ft. (610mm) above the highest
elevation of any part of the Mobile Home within
10 ft. (3048mm) of the chimney.
7) The chimney system shall comply with Local
Requirements.
8) Any openings in a chimney guard where
required must not permit the entrance of 3/4"
(19mm) diameter rod.
9) CAUTION: THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME ROOF, FLOOR, WALLS
AND CEILING MUST BE MAINTAINED.
10) Check any other local building code as other
local codes may apply.
11) WARNING: DO NOT INSTALL IN A SLEEP-
ING ROOM OF A MOBILE HOME.
12) Use silicone to create an effective vapour
barrier at the location where the chimney or
other component penetrates to the exterior of
the structure.