115volts
Table of Contents

Advertisement

Check power source.
Check control switch
setting.
Compressor fails to
start.
Drop of power voltage.
Defect of compressor
capacitor.
Capacitor check.
Replacement.
Irregular motor resistance ( )
Irregular motor insulation ( )
Replacement of compressor
(Motor damaged).
Fails to Start
Improper thermostat
setting
Loose terminal
connection
Improper wiring
—15—
Check circuit breaker
and fuse.
Gas leakage of capillary
bulb on thermostat.
Check control switch.
Fan only fails to start.
Improper wiring.
Defect of fan motor
capacitor.
Irregular motor
resistance ( )
Irregular motor
insulation ( )
Replacement of fan motor.
Regular but fails to start.
Replacement of compressor.
(Locking of piston, metal.)