Page 1
Please complete and mail the owner registration card furnished with this product or register on-line at www.friedrich.com (USA only). For your future convenience, record the model information here. MODEL NUMBER...
Your Friedrich ZStar ® is designed for maximum comfort and quietness. Table of Contents Introduction .................. 2 Safety Precautions ............... 3 How to operate your Friedrich ZStar® ........5 Installation Instructions ............... 7 Troubleshooting Tips ..............12 Warranty ..................13...
Introduction Before Operating Your Unit Make sure the wiring is adequate for your unit. If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. DO NOT use an extension cord.
• If the power cord is damaged, it must generation. be replaced by the manufacturer or a Friedrich-certified service agent. • It will cause electric shock or fire • It will cause electric shock.
Page 5
Safety Precautions CAUTION • They are sharp and may cause • Since the fan rotates at high • Water may enter the unit and an injury. degrade the insulation. It may speed during operation, it may cause an electric shock. cause an injury.
How to operate your Friedrich ZStar Function Controls FUNCTION CONTROL . oo This dial allows you to select 2 cooling and 2 fan speeds. Turn to Off to turn everything off. Turn to Hi Cool for quick cooling. F_a°o .&°o, Turn to Lo Cool to maintain a desired temperature.
Page 7
How to operate your Friedrich ZStar Additional controls and important information. Air Direction •ADJUSTING THE AIR D/RECTION US/NG THE HOR/ZONTAL A/R-DEFLECTOR CONTROL Using the Control Tabs, the air flow can be directed to the left, right, straight ahead, or any combination of these directions.
Installation Instructions Learning the key components will help you properly install the unit. Features 1. CABINET 6. AIR FILTER 2. HORIZONTAL AIR DEFLECTOR 7. KNOBS 3. COOL AIR DISCHARGE 8. AIR INTAKE 4. FRONT GRILLE 9. UPPER GUIDE 5. INLET GRILLE...
Page 9
Installation Instructions Window Requirements NOTE: All supporting parts should be secured to firm wood, masonry, or metal. 1. This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 13" from the bottom of the sash to the window stool.
Page 10
Installation Instructions A. BEFORE INSTALLATION 1. Insert the Guide Panels into the guides of the air TYPE A conditioner. Fasten the Curtains to the unit with screws (TYPE A), as shown Fig. 6. 2. Cut the adhesive-backed seal strip (TYPE D) to the window width.
Page 11
Installation Instructions 4. SECURE THE GUIDE PANELS L BRACKET TYPE A--- Extend the Guide Panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as SASH SEAL shown in Fig. 12. (TYPE E) TYPE B 5.
Page 12
Electrical Safety 115V~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button.
Troubleshooting Tips Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high.
• FAX (210) 357-4490 ROOM AIR CONDITIONERS LIM ITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner...
Need help?
Do you have a question about the ZStar ZQ05 and is the answer not in the manual?