3-1. Specifications

Rated Welding Output
Rated Welding Output
165 A @ 25 Volts AC, 20% Duty Cycle
*While idling

3-2. Duty Cycle Charts

200
180
160
140
120
100
80
0
SECTION 3 − INSTALLATION
Amperage
Range
Range
30 − 205A
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
2 Minutes Welding
20
Amperes Input at Rated Load
Max Open-
Output, Single-Phase
Circuit
Circuit
Voltage
220 V (50 Hz)
47.5
80 VAC
7.6*
8 Minutes Resting
40
60
% Duty Cycle
230 V (60 Hz)
47.5
2.3*
Duty Cycle is percentage of 10 minutes
that unit can weld at rated load without
overheating.
Y 20% Duty Cycle at 165 Amperes. Ex-
ceeding duty cycle can damage unit
and void warranty.
80
100
OM-949 Page 9
Weight
Weight
83 lb
(38 kg)