Step 8 Wiring The Fireplace - Heat-N-Glo 8000 DVTFL Installer's Manual

Table of Contents

Advertisement

Step 8
Wiring the
Fireplace
CAUTION
NOTE: MODEL SL-42DVT
DOES NOT HAVE A HI-TEMP
LIMIT SWITCH.
Figure 30. Standing Pilot Ignition Wiring Diagram
31
NOTE: Electrical wiring must be installed by a
licensed electrician.
For Standing Pilot Ignition Wiring
Appliance Requirements
• This appliance DOES NOT require 110-120 VAC to
operate.
WARNING
DO NOT CONNECT 110-120 VAC TO THE
GAS CONTROL VALVE OR THE
APPLIANCE WILL MALFUNCTION AND
THE VALVE WILL BE DESTROYED.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction box
before the fireplace is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet (7.8 m) or less
length of 18 A.W.G. minimum wire and connect it to
the fireplace ON/OFF switch pigtails.
WARNING
DO NOT CONNECT 110-120 VAC TO THE
REMOTE WALL SWITCH OR THE
CONTROL VALVE WILL BE
DESTROYED.
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.