Installing Vent Components - Heat-N-Glo 8000 DVTFL Installer's Manual

Table of Contents

Advertisement

1. Apply the stove ce-
ment.
2. Line up the internal
beads and rotate the
pipe sections clock-
wise until locked.
3. Lock the vent compo-
nents into place.
4. Check the seal on the
rope gasket.
17
B. Installing Vent Components
1. Attach the First Vent Component to the
Starting Collars
To attach the first vent component to the starting
collars of the fireplace:
• Apply a 3/8 inch (9.5 mm) bead of stove cement
around the inner pipe fireplace starting collar.
• Make sure that the fireplace rope gasket supplied
with the fireplace seals between the first
vent component and the outer fireplace wrap.
• Lock the vent components into place by sliding the
concentric pipe sections with four (4) equally
spaced interior beads into the fireplace collar or
previously installed component end with four (4)
equally spaced indented sections.
• When the internal beads of each outer pipe line up,
rotate the pipe section clockwise about one-quarter
(1/4) turn. The vent pipe is now locked together.
• The first 90° elbow installed in the vent system of a
rear venting fireplace MUST BE in a vertical posi-
tion.
STARTING
STARTING
COLLAR
COLLAR
FIRST
FIRST
VENT
VENT
COMPONENT
COMPONENT
Figure 15. Attaching the First Vent Component to
the Starting Collars
WARNING
A 3/8 INCH (9.5 MM) BEAD OF STOVE
CEMENT MUST BE PLACED AROUND
THE INNER PIPE FIREPLACE
STARTING COLLAR BEFORE
ATTACHING THE FIRST VENT
COMPONENT. FAILURE TO SEAL THIS
JOINT MAY CAUSE THE FIREPLACE TO
OPERATE IMPROPERLY. SEE THE
DIAGRAM .
STOVE
STOVE
SEALANT
SEALANT
BEAD
BEAD
3/8" (9.5 mm)
3/8" (9.5 mm)
3/8 INCH (9.5 mm)
1 INCH (25.4 mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000 dvtfl6000 xlt6000 archSl-42 dvt

Table of Contents