VenTInG

Use Only Approved Venting
The.Clarity.gas.heater.is.tested.and.listed.for.connection.
to.a.4".(100.mm).listed.Class.B.venting.system..
If.the.unit.is.installed.to.vent.through.an.approved.masonry.
chimney. or. a. factory-built. chimney. system,. an. approved.
Class.B.chimney.liner.must.be.used..
Observe.local.codes.when.venting.the.Clarity..If.no.local.
codes.exist,.follow.the.current.edition.of.ANSI.Z223.1.and.
CAN1-.B149.installation.codes..
Do not connect the venting to the flue of a chimney that
serves.a.separate.solid-fuel.burning.appliance.
The.venting.manufacturer's.installation.instructions.must.
be.followed.exactly.
IMPORTANT: Because of the high efficiency and low
flue gas temperatures of this appliance, it is important that
it be connected to a well-sealed and efficient venting system
which.is.capable.of.registering.a.negative.pressure.while.
the.stove.is.in.operation.
The most efficient venting systems are those that have a
minimum.number.of.bends.and.minimal.horizontal.runs.
The.Clarity.gas.heater.is.equipped.with.a.thermally.acti-
vated.vent.safety.switch.that.will.shut.down.the.main.burner.
if.the.heater.is.not.properly.venting..The.safety.switch.will.
automatically.reset.after.the.heater.has.cooled.down.
The. switch. will. continue. to. cycle. off. and. on. until. the.
venting.problem.is.corrected..If.you.are.unable.to.correct.
the.venting.problem,.seek.expert.advice.from.your.Harman.
dealer.or.installer.
Do noT DIsConneCT oR bYPass THe VenT
safeTY sWITCH.
WARNING: Operation of this heater when not con-
nected to a properly installed and maintained venting
system or tampering with the vent safey shutoff system
can result in carbon monoxide (Co) poisoning and pos-
sible death.
The.Clarity.gas.heater.is.equipped.with.its.own.internal.
draft.hood.so.no.additional.external.draft.hood.is.required..
The.heater.should.be.installed.so.that.the.draft.hood.is.in.
the.same.atmospheric.pressure.zone.as.the.air.inlets.to.the.
heater.
TesT foR flUe sPIllaGe
A.spillage.test.should.always.be.made.at.the.completion.
of.the.installation.
1..Start.all.exhaust.fans.in.the.home.and.then.close.all.
doors.and.windows.in.the.room.containing.the.heater.
2..Light.the.heater.and.allow.it.to.run.for.5.minutes.on.the.
high.output.setting..If.the.convection.air.blower.is.installed,.
it.should.be.turned.off.for.the.test.
3..Hold.a.match.or.other.source.of.smoke.near.the.draft.
hood.outlet.on.the.upper.back.of.the.stove..
4..If.the.smoke.is.not.drawn.in,.turn.off.the.heater.and.
determine.the.cause.of.the.lack.of.draft..If.necessary,.seek.
expert.advice.
For. sites. with. swirling. or. turbulent. wind. conditions,. a.
wind.cap.may.solve.the.problem.