Appendix.B
De-RaTInG foR HIGH alTITUDe
For. U.S.. installations,. the. Clarity. B-Vent. is. approved.
for.elevations.up.to.2000.feet.using.the.factory-installed.
burner.injectors..At.elevations.above.2000.feet,.U.S..codes.
require.a.decrease.in.the.input.rating.by.changing.the.burner.
injectors.to.a.smaller.size..The.chart.below.lists.by.part.
numbers.the.appropriate.injectors.for.both.LP.and.natural.
gas.at.various.altitudes.
For. Canadian. installations,. the. Clarity. B-Vent. is. ap-
proved. for. elevations. up. to. 610. meters. (2000. feet).. For.
installations. from. 610-1370. meters. (2000-4500. ft.). the.
orifice sizes (DMS) for natural and propane gas are as
shown.in.the.chart.below.
naTURal Gas
front
altitude
Injector Part no.
0-2000'.
47.
2000-3000'.
48.
3000-4000'.
49.
4000-5000'.
49.
5000-6000'.
50.
6000-7000'.
50.
7000-8000'.
51.
8000-9000'.
51.
PRoPane
front
altitude
Injector Part no.
0-2000'.
56.
2000-3000'.
56.
3000-4000'.
56.
4000-5000'.
57.
5000-6000'.
57.
6000-7000'.
57.
7000-8000'.
58.
8000-9000'.
58.
●When ordering injectors that have no Harman
Part number, specify Male or feMale and
the appropriate 2- digit number.
THe ConVeRsIon sHall be CaRRIeD oUT
bY a ManUfaCTUReR's aUTHoRIZeD ReP-
ResenTaTIVe In aCCoRDanCe WITH THe
ReqUIReMenTs of THe ManUfaCTUReR,
PRoVInCIal oR TeRRIToRIal aUTHoRITIes
HaVInG JURIsDICTIon anD In aCCoRDanCe
WITH THe ReqUIReMenTs of THe CURRenT
eDITIon of Can/CGa-b141.1 oR Can/CGa-
b141.2 InsTallaTIon CoDes.
Harman
Center
Injector Part no.
3-40-64347.
56.
MALE.
56.
MALE.
56.
MALE.
57.
MALE.
57.
MALE.
57.
MALE.
58.
MALE.
58.
Harman
Center
Injector Part no.
3-40-57356.
71.
3-40-57356.
71.
3-40-57356.
71.
MALE.
71.
MALE.
71.
MALE.
71.
MALE.
71.
MALE.
71.
. For. high. altitude. installations. consult. the. local. gas. dis-
tributor.or.the.authority.having.jurisdiction.for.proper.rating.
methods.
NOTE:. The. difference. in. altitude. derating. requirements.
for.the.U.S..and.Canada.is.simply.a.result.of.differences.in.
testing.standards.between.the.two.countries.
If.the.installer.must.convert.the.unit.to.adjust.for.varying.
altitudes,.an.information.sticker.like.the.one.below.must.be.
filled out and affixed to the appliance at the time of conver-
sion.
Harman
Rear
Injector Part no.
3-40-57356.
39.
3-40-57356.
40.
3-40-57356.
41.
MALE.
42.
MALE.
42.
MALE.
43.
MALE.
43.
MALE.
44.
Harman
Rear
Injector Part no.
3-40-57271.
53.
3-40-57271.
54.
3-40-57271.
54.
3-40-57271.
54.
3-40-57271.
55.
3-40-57271.
55.
3-40-57271.
56.
3-40-57271.
56.
This.appliance.has.been.converted.for.use.at.an.altitude.of.__________ft.
Orifice Sizes: Front ________
Input.(Btu/hr)............._________________
Manifold.Pressure......__________________
Fuel.Type............_______________________
Converted.By...._________________________________
Date.of.Conversion.._______________________________
1
Harman
nominal btu
Input Rate
3-40-64739.
40,000.
MALE. .
38,400
MALE. .
36,900
MALE. .
35,400
MALE. .
34,000.
MALE. .
32,600
MALE. .
31,300
MALE. .
30,100
Harman
nominal btu
Input Rate
3-40-57753.
40,000.
MALE. .
36,900
MALE. .
36,900
MALE. .
35,400.
MALE. .
32,600.
MALE. .
32,600.
3-40-57356.
30,100.
3-40-57356.
30,100
Center_________
Rear ________