Connecting the water inlet hose
Important!
The appliance should be connected to the water main using only the new hose supplied with the
dishwasher. Old hose sets should not be used.
Check water connection requirements.
1
The dishwasher has a single valve water connection.
We recommend a cold water connection.
The incoming water temperature should not exceed 25 ºC.
Check water pressure.
2
Permitted water pressure extremes
Lowest: 0.3 bar = 3 N/cm
When pressure is below 1 bar, contact a qualified technician.
Highest: 10 bar = 100n/cm2 = 1Mpa
When pressure is above 10 bar, a pressure reduction valve must
be installed. Contact a qualified technician.
Connect the water inlet hose to an accessible water tap using a ¾" bsp connector.
3
The valve box of the AQUASAFE+ anti-flood protection system is already fitted on the hose.
For details, see 'About the AQUASAFE+ anti-flood protection system' below.
If required, use a filter insert (Part No. 420016P) to filter out deposits from the piping. It is
available from the nearest Authorised Service Agent.
Tighten the hose coupling a further half turn after seal contact.
4
Ensure incoming water is clear.
5
If the water pipes have not been used for a long period of time, let the water run to make sure it
is clear with no impurities. Not doing so may result in the water inlet hose getting blocked and
damaging the appliance.
Check that the connection does not leak.
6
About the AQUASAFE + anti-flood protection system
The Aquasafe+ System protects against water damage by stopping the water flowing in the
event of a damaged hose or a leak within the machine.
Do not immerse the system's valve box into water; it contains electrical components.
In case of damage, pull out the power supply plug.
Do not shorten or lengthen the water inlet hose insert as it contains electrical cables and
components.
Connecting the drain hose
For drain hose connection options and requirements, see the illustrations opposite.
If a drain hose extension is required, a drain hose of equal quality and not longer than 4 m must
be used. Using a hose longer than 4 m will produce poorer cleaning results.
2
= 30kPa
Installation instructions
hose
coupling
¾ " bsp connector
min 10 mm
1010
valve box
water inlet
hose
Fig. 1 Connecting the water
inlet hose (Aquasafe+
system already fitted)