Haier RDE 350AW User Manual And Installation Instructions page 17

Gas & electric dryer
Hide thumbs Also See for RDE 350AW:
Table of Contents

Advertisement

Available languages

Available languages

CONNECTING THE DRYER TO THE GAS SUPPLY
A) Connect female 3/8" NPT elbow to gas
inlet on dryer. Then connect 3/8" flare
union adapter to female elbow.
IMPORTANT: To prevent the inlet from
B) Attach the flexible metal gas line connector
to the adapter.
C) Make sure flexible gas line seal is secure.
Use two wrenches for the best possible
connection.
D) To check gas inlet pressure, attach 1/8"
NPT plugged tapping to dryer gas line shut-
off valve. Then connect flare union adapter
to plugged tapping. Affix Teflon® tape
to the threads of the adapter and plugged
tapping to ensure seal.
E) Use two adjustable wrenches to tighten
every connection.
IMPORTANT: Do not overtighten!
F) Open gas shut-off valve.
twisting, please use a pipe
wrench to secure the dryer
gas inlet. Affix Teflon®
tape or pipe compound to
adapter and gas inlet.
English
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents