Frequency, Rotary Switch, Auto Power Off Specification - Milwaukee 2216-20 Repair Service Instructions

Light commercial digital multimeter
Hide thumbs Also See for 2216-20:
Table of Contents

Advertisement

(11) Auto Power Off
The meter automatically turns the power off after powering up and no operation for 20 ± 5 minutes.
To power up, turn the knob back to OFF first.
(12) Measuring Rate: 3 times/sec.
(13) Fuse: 10A/600V Fast Action Fuse
(14) Battery: Alkaline 1.5V Battery * 2
(15) Low Battery Voltage: 2.3V ± 0.1V
(16) Backlight
The meter automatically turns the backlight off after lighting up and no operation for 10 ± 1
minutes.
(17) Battery life (ALKALINE):
Approx. 26 hours with backlight on.
Approx. 360 hours with backlight off.
(18) Overvoltage Category
IEC 61010-1 600V CAT. III
(19) Operating Temperature
<
-10°C ~ 30°C,
80%RH
=
<
30°C ~ 40°C,
75%RH
=
<
40°C ~ 50°C,
45%RH
=
(20) Storage Temperature
-40°C ~ +60°C, 0 ~ 80%RH (No batteries)
7