Required Equipment
Required equipment is listed in Table B. If the recommended models are not available, equipment
with equivalent specifications may be used.
Repairs or servicing should be performed only by qualified personnel.
Table B. Required Equipment
Equipment
AC Voltage Range: 0 ~ 750V AC
Calibrator
Accuracy: ±0.07% (Basic)
Frequency Range: 40 ~ 1kHz
Accuracy: ±2%
DC Voltage Range: 0 ~ 1000V DC
Accuracy: ±0.006% (Basic)
Current Range: 0 ~ 20A
Accuracy: AC (40Hz to 1kHz): ±0.08% (Basic)
Frequency Source: 0.5Hz ~ 100kHz
Accuracy: ±0.001%
Amplitude: 0.5V p-p ~ 600V p-p
Accuracy: ±5%
Resistance Range: 1Ω ~ 100MΩ
Accuracy: ±0.03% (Basic)
Capacitance Range: 0.1uF ~ 1100uF
Accuracy: ±0.10% (Basic)
Required Characteristics
DC: ±0.02% (Basic)
9
Recommended Model
Fluke 5500 or Wavetek
9100 Calibrator or
equipment