Standby Timer Timeout Period; Sleep Command (99 H , E6 H ); Automatic Reallocation - Seagate Medalist Pro Series Product Manual

Medalist pro family ata interface drives
Hide thumbs Also See for Medalist Pro Series:
Table of Contents

Advertisement

34
Medalist Pro 6450/5040 Product Manual, February 1997

3.2.3 Standby timer timeout period

The Idle command and Standby command Sector Count registers are
used to activate the Standby timer. The host can enable the Standby
timer by placing a value in the sector-count register of the Idle command
or Standby command. The value corresponds to a predetermined period
of drive inactivity. The table below lists the values the Seagate drives use
and their corresponding timeout period.
Sector Count Register contents
0 (0
)
H
1–12 (1
–C
)
H
H
13–240 (D
–F0
)
H
H
241–251 (F1
–FB
)
H
H
252 (FC
)
H
253 (FD
)
H
254 (FE
)
H
255 (FF
)
H
The drives are shipped with the Standby timer disabled.
3.2.4 Sleep command (99
This command performs the same function as the Standby Immediate
command (94
, E0
).
H
H

3.2.5 Automatic Reallocation

This feature allows the drive to identify grown media defects and to
reallocate the sector without host intervention using both Read and Write
Automatic Reallocation.
You can disable Read Reallocation by using the Set Features command
Disable Read Automatic Reallocation, feature value 84
not used for the Read Long command.
Corresponding timeout period
Timeout disabled
value = 60 seconds
(value * 5) seconds
(value – 240) * 30) minutes
21 minutes
8 hours
Reserved
21 minutes 15 seconds
, E6
)
H
H
. This feature is
H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Medalist pro 6450Medalist pro 5040St36450aSt35040a

Table of Contents