Digital Outputs; General - RME Audio Fireface UCX User Manual

Usb 2.0 / firewire 400 digital i/o system 8 + 8 + 2 channels analog / adat / spdif interface 24 bit / 192 khz digital audio 36 x 18 matrix router 2 x midi i/o stand-alone operation class compliant operation midi remote control
Hide thumbs Also See for Fireface UCX:
Table of Contents

Advertisement

ADAT Optical
• 1 x TOSLINK
• Standard: 8 channels 24 bit, up to 48 kHz
• Double Speed (S/MUX): 4 channels 24 bit 96 kHz
• Quad Speed (S/MUX4) : 2 channels 24 bit 192 kHz
• Bitclock PLL ensures perfect synchronisation even in varispeed operation
• Lock Range: 31.5 kHz – 50 kHz
• Jitter when synced to input signal: < 1 ns
• Jitter suppression: > 30 dB (2.4 kHz)
AES/EBU - SPDIF
• 1 x RCA and 1 x optical, according to IEC 60958
• High-sensitivity input stage (< 0.3 Vpp)
• Accepts Consumer and Professional format, copy protection will be ignored
• Lock Range: 27 kHz – 200 kHz
• Jitter when synced to input signal: < 1 ns
• Jitter suppression: > 30 dB (2.4 kHz)

31.5 Digital Outputs

Word Clock
• BNC
• Max. output voltage: 5 Vpp
• Output voltage @ 75 Ohm termination: 4.0 Vpp
• Output impedance: 10 Ohm
• Frequency range: 27 kHz – 200 kHz
ADAT
• 1 x TOSLINK
• Standard: 8 channels 24 bit, up to 48 kHz
• Double Speed (S/MUX): 4 channels 24 bit 96 kHz
• Quad Speed (S/MUX4) : 2 channels 24 bit 192 kHz
AES/EBU - SPDIF
• 1 x RCA and 1 x optical, according to IEC 60958
• Output level Professional 1.4 Vpp, Consumer 0.7 Vpp
• Format Professional according to AES3-1992 Amendment 4
• Format Consumer (SPDIF) according to IEC 60958
• Single Wire mode, sample rate 28 kHz up to 200 kHz

31.6 General

• Power supply: external power supply
• Typical power consumption: 13 Watts
• Current at 12 Volt operating voltage: 910 mA (11 Watts)
• Dimensions including rack ears (WxHxD): 265 x 44 x 165 mm (10.5" x 1.73" x 6.5")
• Dimensions without rack ears/handles (WxHxD): 218 x 44 x 155 mm (8.6" x 1.73" x 6.1")
• Weight: 1.5 kg ( 3.3 lbs)
• Temperature range: +5° up to +50° Celsius (41° F up to 122°F)
• Relative humidity: < 75%, non condensing
• Included power supply: Internal switching PSU, 100 - 240 V AC, 2 A, 24 Watts
User's Guide Fireface UCX © RME
90

Advertisement

Table of Contents
loading

Table of Contents