ADJUSTING THE DIRECTION OF AIR CIRCULATION

● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Controller.
● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airfl ow-direction louvers have
stopped moving.
Vertical Air Direction Adjustment
Press the SET button (Vertical) (Fig. 6 R).
Each time the button is pressed, the air direction range will change as follows:
1
Types of Air fl ow Direction Setting:
1,2,3 : During Cooling/Dry modes
1,2,3,4,5,6 : During Fan mode
The Remote Controller's display does
not change.
● Use the air direction adjustments within the ranges shown above.
● The vertical airfl ow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry/Fan mode : Horizontal fl ow 1
● During AUTO mode operation, for the fi rst minute after beginning operation,
airfl ow will be horizontal 1; the air direction cannot be adjusted during this pe-
riod.
● Direction 1
2
Only the direction of the Air Flow Direction Louver changes; the direction of the
Power Diffuser does not change.
Horizontal Air Direction Adjustment
Press the SET button (Horizontal) (Fig. 6 S).
● Each time the button is pressed, the air direction range will change as follows:
1
The remote controller's
display does not change.
9315345363_OM.indb Sec1:10
9315345363_OM.indb Sec1:10
2
3
4
5
1
2
3
4
5
6
2
3
4
5
1
2
3
4
● Never place fingers or foreign objects
6
● Always use the Remote Controller's
● During Cooling and Dry modes, do not
● When used in a room with infants,
5
DANGER!
inside the outlet ports, since the internal
fan operates at high speed and could cause
personal injury.
SET button to adjust the vertical airfl ow
louvers. Attempting to move them
manually could result in improper
operation; in this case, stop operation
and restart. The louvers should begin
to operate properly again.
move the vertical air direction louvers
outside their proper operating range
for the mode (1 - 3) and into the fan
region (4 - 6); using the louvers in
the fan region will cause moisture to
condense near the air outlet, and water
may drop onto the fl oor. During the
Cooling/Dry modes, if the louvers are
operated outside the range 1 - 3 for
more than 20 minutes, they will be au-
tomatically returned to the 3 range.
children, elderly or sick persons, the
air direction and room temperature
should be considered carefully when
making settings.
En-10
9/16/2010 2:48:51 PM