Insert test leads in the jacks shown.
1
2
Turn rotary switch to continuity test.
3
Press pushbutton for 2 secs.
4
Clip leads to switch as shown.
5
Press brake pedal and listen for tone. If tone sounds,
stoplight switch is good.
TYPICAL STOPLIGHT SWITCH
BRAKE PEDAL
PIVOT POINT
BRAKE PEDAL
is displayed.
_
4
+
FEMALE
CONNECTOR
5
Figure 8. Testing Continuity in a Switch