Connect The Vent System - Whirlpool GZ7730XGS1 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) slide-out vent range hood
Hide thumbs Also See for GZ7730XGS1:
Table of Contents

Advertisement

Available languages

Available languages

3. Connect the black wire of the power supply cable to the
black wire in the hood with a twist-on connector.
Electrical
Shock Hazard
Electrically
ground blower.
Connect ground
wire to green ground
screw in
terminal box.
Failure to do so can result
in death or electrical shock.
4. Connect the power supply ground wire to the green ground
screw inside the vent hood terminal box.
B
C
A. White wires
B. Green ground screw
C. Ground wire
D. Black wires
E. Twist-on connectors
5. Replace the terminal box cover.
Vented installations:
Replace the metal filter. Connect the vent system to the hood
vent opening. Seal the connection with clamps.
A. Filter
Recirculation
installations:
Connect the vent system to the hood vent opening. Seal the
connection with clamps.
Install Recirculation
Kit (Part Number 883140)
1. Pull out on the range hood to expose the filters.
2. Remove the 2 metal filters.
3. Locate tabs "A" and slots "B" in the opening. This is where
the filter will fit into place.
B
'/
4.
A
A. Tab
B. Slot
Place charcoal filter into opening, resting the back of the filter
on tabs "A," then clip filter tabs "C" into slots "B."
A. Tab
B. Slot
C. Filter tabs
5. Replace metal filters.
6. Reconnect power.
7. Check the operation of the vent hood fan and light.
8. Push the range hood back in.
To order replacement
kits, see the "Assistance
or Service"
section.
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gz7736xgs1Kwvu205yba2

Table of Contents