Troubleshooting; Error Messages - Soleus Air PH1-12R-03 Owner's Manual

Portable air conditioner, dehumidifier, heater and fan utilizing heat pump technology
Hide thumbs Also See for PH1-12R-03:
Table of Contents

Advertisement

TROUBLESHOOTING
Before seeking repair or service, please check the following:
PROBLEM
POSSIBLE CAUSE
REMEDY
Is the unit plugged in?
Securely plug the powercord into the wall outlet.
Is the main powersupply on?
Reestablishthe main powersupply.
Unit does not operate or
only runs in fan mode.
Is the water containerfull indicator light on?
Empty the water container.
Is the timer set?
Changetimer settings.
Is the air inlet or outlet blocked?
Clear the blocking.
Cooling efficiencyis not
Is there any other heatsource in the room?
Move the heat source.
satisfactory.
Are the air filters dirty?
Cleanthe air filters.
Is the temperaturesetting suitable?
Changethe temperaturesetting.
Is the fan speed set at low?
Increasethe fan speed.
Is the machine positionedunevenly on a
Place the unit on a level surface.
Unit is noisy or vibrates,
level surface?
Is the voltage from the powersource correct?
Use a proper power source.
The unit starts and
Position the exhaust hose correctly and keepthe
stops frequently.
Is the exhaust hose positioned incorrectly?
exhaust hosestraight as possible.
ERROR MESSAGES
Diagnostic
system indicators
appear
if any of the following
interrupts
operation
of the unit. The unit may
require simple maintenance
or repair by a qualified
service technician.
CODE
DIAGNOSIS
ACTION
FAULTE1
Faultyroom temperaturesensor
Contact customer servicefor repair or service.
FAULTE2
Faultyinside sensor.
Contact customer servicefor repair or service.
FAULTE3
Internalfrost in the unit.
Wait for unit to defrost
FAULTE4
Unit malfunctions.
Contact customer servicefor repair or service.