  • Page 1 PH5 Series Portable Air Conditioner with Heat Pump Operating Instructions 3092402 PH5(S) SERIES © 2010 Soleus Air International...
  • Page 2: Important Instructions

    Thank you for choosing a Soleus Air PH5 Series Portable Air Conditioner with Heat Pump. This owner’s manual will provide you with valuable information necessary for the proper care and mainte- nance of your new product. Please take a few moments to thoroughly read the instructions and famil- iarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner.
  • Page 3: Package Contents

    These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. • If the ambient temperature is higher than the max operating temperature or lower than the minimum operating tem- perature, the air conditioner may not work properly. MODEL COOLING CAPACITY...
  • Page 4: Lcdi Power Cord And Plug

    3. Press RESET button for use If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
  • Page 5: Product Diagram

    PRODUCT DIAGRAM Louvers Air Filter Compartment and Air Intake Power Cord Wrap Air Intake Control Panel and LED display Casters Remote Control and Holder Exhaust Outlet Drain Plug...
  • Page 6: Parts & Assembly

    INSTALLATION When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air (or cold air in heat mode) out of the room to complete the air exchange. When the unit is operating in fan mode, no outdoor air exchange takes place.
  • Page 7 NOTE: FOR THE PH5 THERE IS ONLY ONE EXHAUST HOSE TO INSTALL NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images show general directions for Soleus Air hose portable air conditioners.
  • Page 8: Window Kit Assembly

    WINDOW KIT ASSEMBLY 1.Parts: A) 2 Track Screws B) 2 Wing Nuts C1 & C2) 2 Hose Panels, one Exhaust Hose Openings D) 1 Sliding Track Panel 2. Assembly: First, take the Track Screws (A) and screw one 3. Next, take the Wing Nuts (B) and tighten them around each of the Track Screws (A).
  • Page 9: Control Panel, Display, & Operating Instructions

    CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL & LED CONTROL DISPLAY CONTROL PANEL TIMER TIME/TEMP DECREASE FAN SPEED LED CONTROL DISPLAY AUTO FAN SPEED OSCILLATION ON/OFF COMPRESSOR ON/OFF TIME/TEMP INCREASE LED CONTROL DISPLAY DEHUM. BUCKET FULL POWER MODE HEAT REMOTE RECEIVER TEMPERATURE AND TIMER...
  • Page 10: Operating The Unit Using The Control Panel

    2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater mode. 3) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High, Medium, and low.
  • Page 11 Heating Mode 1) Install the exhaust hose and window kit properly (see pages 7 & 8 ). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button on the control panel. 4) Press the MODE button until the “...
  • Page 12 Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit.
  • Page 13: Operating The Unit Using The Remote Control

    OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL MODE BUTTON FAN SPEED SWING (LOUVER OSCILLATION) SLEEP BUTTON HOUR SELECTER LCD DISPLAY POWER BUTTON TEMP SETTING TIMER ON TIMER OFF MINUTE SELECTER * Remote color may differ from the image above.
  • Page 14 Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control. 4) Temperature Setting - When the unit is in Air Conditioner or Heating mode you can select your desired temperature. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD dis- play on the remote control will increase or decrease accordingly.
  • Page 15: Maintenance

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.
  • Page 16: This Warranty Does Not Cover

    One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air PH5 Series Portable Air Conditioner to be free of de- fects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.