Air filter indicator

To install the air filter indicator:
1.
Mount the manometer to the side of the spray
booth by threading the M4 x 45 tap screws
into the pre-drilled holes (figure 15).
figure 15. Mounting manometer to spray booth.
2.
Adjust the manometer so the built-in level
reads level (figure 15).
3.
install a tubing connector fitting in the larger
pre-drilled hole on the side of the booth near
the manometer as shown in figure 16.
Model g0533 (Mfg. since 3/11)
figure 16. tubing installed onto spray booth
4.
run tubing from the low pressure side (-) of
the manometer to the tubing connector fitting
as shown in figure 16.
Built-in
level
5.
install tubing into the high pressure side (+) of
the manometer and secure it with the plastic
clip and an M4 x 12 tap screw as shown in
figure 17.
plastic
Clip
chamber.
figure 17. tubing secured with clip.
tubing
Connector
Fitting
-17-