Appendix E: Notes On Using The Drawer Kick-Out Connector - Epson TM-U220A Specification

One-station
Hide thumbs Also See for TM-U220A:
Table of Contents

Advertisement

Confidential
APPENDIX E: NOTES ON USING THE DRAWER KICK-OUT
CONNECTOR
1) Drawer specifications (See Section 2.3.2, Drawer kick-out connector.)
Drawer specifications differ significantly depending on manufacturer and model number. Make
sure that the specifications of the drawer used meet the following conditions when connected to
the drawer kick-out connector. These conditions also apply to any equipment (other than a
drawer) that is connected to the drawer kick-out connector.
Never use a drawer (or other equipment) that does not meet all of the following conditions:
• The load, such as a drawer kick-out solenoid, must be connected between pins 4 and 2 or
pins 4 and 5 of the drawer kick-out connector. (*1)
• When the drawer open/close signal (indicating the state of the drawer) is used, a switch must
be provided between drawer kick-out connector pins 3 and 6. (*2)
• The resistance of the load, such as a drawer kick-out solenoid, must be 24 Ω or more or the
input current must be 1 A or less. (*3)
• Be sure to use the 24 V power output on drawer kick-out connector pin 4 for driving the
equipment. Never connect any other power supply to the drawer kick-out connector. (*4)
The peak current is 1 A. See item 2) below for drive signal duty.
NOTES : (*1): Proper operation is not guaranteed with different connections.
(*2): Proper operation is not guaranteed with different connections or connection to a
(*3): Connection to equipment whose resistance is less than 24 Ω or less or whose
(*4): Operation is not guaranteed with other power supplies.
2) Notes on the pulse generating command (ESC p)
When using ESC p to drive the drawer connected to the drawer kick-out connector, set the
command parameters to meet the following conditions:
ESC
p
ON time
ON time + OFF time
or, OFF time ≥ ON time × 4 ....................................................................... Formula E-2
EPSON
component other than a switch.
input current is 1 A or more may damage the connected equipment as well as
the printer.
m
t1
t2
≤ 0.2 ...................................................................... Formula E-1
TITLE
TM-U220A
Specification
(For Argentina Fiscal)
OFF time
ON time
SHEET
REVISION
NO.
NEXT
SHEET
A
App.10
App.9

Advertisement

Table of Contents
loading