Installation - Whirlpool RF3010XEW0 Use And Care & Installation Instructions Manual

Electric range
Hide thumbs Also See for RF3010XEW0:
Table of Contents

Advertisement

INSTALLATION
STEPS
Electrical connections to the ranae
Use only a 3-conductor, or if required, a 4-conductor range cord. The range power-supply
cord used must be
rated 250 Volts 40 Amperes and marked for use with ranges. The range power-supply
cord must have open
end spade lugs with upturned ends or closed loop terminals,
NOTE: A 4-conductor cord is to be used only when the appliance is installed in a mobile home or where local
codes do not permit grounding through the neutral.
TO MAKE 3-CONDUCTOR
CONNECTION:
1. Remove screws holding the terminal
block cover plate located on the outer
back of the range.
2. Insert range cable or connector through
opening below terminal block.
3. Connect the cord strain relief to the
power supply cord which must be secure-
ly attached to the cord set.
4. Connect the neutral (center) supply lead
to the center connection on the terminal
block using the hex nut provided.
5. Connect the (2) outside supply leads to
the corresponding
outside terminals using
the hex nuts provided.
neutral
neutral
TE BLOCK
| f
_ _
GROUND STRAP
'____
(LINK)
_-
CONDUIT BRACKET
inch Cable assembly
Range power-supply
cord
NOTE: Re-locate the conduit bracket for the
selected electrical connection,
cord
or cable, center the conduit bracket
below the terminal block, Secure with
(3) metal screws to range rear wall,
Special grounding
instructions
for 4-wire systems
WARNING: Frame grounded to neutral of appliance through a link. If used in a MOBILE HOME or if LOCAL
CODES do not permit grounding through the neutral:
1. Remove the 3-conductor cord (if provided).
2. Cut the ground strap link between the terminal block and the secured end of the link.
3. Using the upturned ends of the ground link and green ground screw from the secured end, attach the ground
lead to the unit in accordance with local codes.
4. Connect neutral terminal or lead to the branch circuit neutral in usual manner. (If the appliance is to be
connected by means of a cord kit, use a 4-conductor cord for this purpose.