Hunter Ellipse 90064 Owner's Manual page 7

Bath ventilator with light and night light
Hide thumbs Also See for Ellipse 90064:
Table of Contents

Advertisement

Available languages

Available languages

0 A17
Connect 4" duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
A19
Reinstall the motor by inserting the tabs and pushing up into
position. Make sure the wires are not pinched
between the motor and the housing.
A21
Turn on the power source.
A18
A20
H
A22
7
41722-01 09/09/2011
H
Connect wiring from the motor to the wiring cover plate.
I
Secure the motor by tightening the 2 screws.
O N
Test the motor. If the motor does not run,
check the plug connection.
O F F

Hide quick links:

Advertisement