Range Hood Safety; Installation Instructions; Install Range Hood - Whirlpool UXT4230AAW0 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
NOTE: For vented installations, it is recommended
that the vent
/
system be installed before hood is installed,
i
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
1. For vented installations, determine which venting method to
use: roof or wall.
'_
2. Select a flat surface for assembling the range hood. Place
covering over that surface.
(_l
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
71/d '
i
(19cm) I
i
i
Centedine
2" (5.1cm)
from wall,
not cabinet
frame
To wire through rear wall:
Mark a line 71/2"(19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is 34" (1.9 cm) from
underside of cabinet. Drill a 1W' (3.0 cm) diameter hole
through wall at this point.
3,
4.
Using 2 or more people, lift the range hood onto covered
surface.
If cabinet has recessed bottom, add wood filler strips on each
side. Install screws to attach filler strips in locations shown.
Wood filler strips
(recessed cabinet
bottoms only)
(7.6 cm)
3" (7.6 cm)
Wall
Determine
Wiring Hole Location
Cut only one 1V4" (3.2 cm) diameter wiring access hole. See Step
2 for wiring hole location instructions.
Either wiring hole can be
used.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
A. Centerline
h
2,
To wire through
top:
Mark a line 71/2 '' (19.0 cm) from the right of the centerline on
the underside of the cabinet. Mark the point on this line that is
2" (5.0 cm) from back wall. Drill a 11¼ '' (3.0 cm) diameter hole
through the cabinet at this point.
i
_,"(t.9cm)
i
i 71/2"
|1,,
i
' (19cm)
Centedine
Style 1 - Cut Openings for 31/4 '' x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4" x 101/2"(10.2 cm x 26.7 cm) rectangular cutout on
the underside of cabinet top and bottom:
1. Mark lines 11/2 '' (3.8 cm) and 51/2 '' (14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼ '' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents