KitchenAid KSRG25FVMS00 User Instructions page 13

Hide thumbs Also See for KSRG25FVMS00:
Table of Contents

Advertisement

Available languages

Available languages

Base Grille Water Filtration System
Model TIWG2L/T2RFWG2
Capacity
200 Gallons (758 Liters)
Model TIWG2/T2RFWG2
Capacity
200 Gallons
(758 Liters)
@
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I1"; and against
NSF/ANSI
Standard
53 for the reduction
of
Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to NSF/ANSI
42/53 for the reduction
of the substances
listed below. The concentration
of the
indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit for water
leaving the system,
as specified
in NSF/ANSI
42/53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I1"
Contaminant
Reduction
Lead: @ pH 6.5***
Lead: @ pH 8.5***
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Carbofuran
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
0.04 mg/L
Average
Influent Challenge
Maximum
Average
Minimum %
Influent
Concentration
Effluent
Effluent
Reduction
2.0182 mg/L
2.0 mg/L + 10%
0.06 mg/L **
0.0536 mg/L
97.03
1333333 #/mL
At east 10,000 part c es/mL
6600 #/mL
2325 #/mL
99.51
Average
Influent Challenge
Maximum
Average
Minimum %
Influent
Concentration
Effluent
Effluent
Reduction
0.1533 mg/L
0.1400 mg/L
0.0058 mg/L
0.0059 mg/L
0.0154 mg/L
1.7571 mg/L
O.O15 mg/L
0.0819 mg/L
0.15 mg/L + 10%
0.15 mg/L_+ 10%
0.006 mg/L + 10%
0.006 mg/L _+10%
0.015 mg/L _+10%
1.8 mg/L _+10%
0.015 mg/L _+10%
0.08 mg/L _+10%
0.0005 mg/L
0.0007 mg/L
0.0002 mg/L
0.0005 mg/L
0.0012 mg/L
0.0250 mg/L
0.001 mg/L
0.0400 mg/L
0.0005 mg/L
0.0006 mg/L
0.0002 mg/L
0.0003 mg/L
0.0006 mg/L
0.0066 mg/L
0.001 mg/L
0.0213 mg/L
99.67
99.50
96.54
91.57
92.22
98.58
93.33
51.13
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted.
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements
be carried out for the product to
perform as advertised.
Use replacement filter T2RFWG2, part #4396841. In Canada,
use replacement filter T2RFWG2, part #4396841 B.
2008 suggested retail price of $39.99 U.S.A./S49.99 Canada.
Prices are subject to change without notice.
Model TlWG2L: Style 1 - Press FILTER to check the status
of your water filter. If the filter indicator light is yellow, order a
new filter. If the filter indicator light is red, it is recommended
that you replace the filter.
Style 2 - When the filter indicator reads 10%, order a new
filter. When the filter indicator reads 0%, it is recommended
that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended
that you
replace the filter.
Model TlWG2:
Change the water filter every 6 months
depending upon your usage. If the water flow to the water
dispenser or ice maker decreases noticeably before 6 months
have passed, replace the water filter more often.
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions,
actual performance may vary.
Flow = 0.5 gpm
(1.9 Lpm). Pressure
= 60 psig (413.7
kPa).
Average
%
Reduction
97.34
99.83
Average
%
Reduction
99.67
99.57
96.54
94.92
96.34
99.63
93.33
74.00
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system.
Refer to the "Assistance
or Service" section for the
Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.5 gpm (1.9 Lpm) @ 60 psi
*Class II particle size: 1 um to <5 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
***Compliant
for Lead reduction requirements
under NSF/ANSl Standard 53 as tested by Pace Analytical Services, Inc.
® NSF is a registered trademark
of NSF International.