Gas Hook Up - Jenn-Air 720-0062-LP Manual

Stainless steel gas grill
Hide thumbs Also See for 720-0062-LP:
Table of Contents

Advertisement

GAS HOOK-UP
Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure regulator and hose assembly
must be specified by the grill manufacturer.
This is a liquid propane configured
grill. Do not
attempt to use a natural gas supply unless the grill
has been pre-configured
for natural gas use.
Total gas consumption (15brhour) of the 720-0062-
LP grill with all burners set on "HI":
Main burners
48,000 BTUfHr.
Rear burners
10,000 BTUIHr.
Side burner
12,000 BTU/Hr.
Total
70,000 BTUIHr.
The installation of this appliance
must conform with
local codes or, in the absence
of local codes, with
the national fuel gas code, ANSI Z223. 1.
installation
in Canada must be in accordance
with
the Standard
CANICGA-B149.2
(installation
code
for gas burning appliances
and equipment)
and
local codes.
LP GAS CYLINDER
REQUIREMENTS
(20lb. Cylinder)
A dented or rusty LP gas cylinder may be
hazardous
and should be checked by your LP
supplier. Never use a cylinder with a damaged
valve. The LP gas cylinder
must be constructed
and marked in accordance
with the specifications
for LP gas cylinders
by the United States
Department
of Transportation
(DOT) or the National
Standard of Canada, CANICSA-B339,
Cylinders,
Spheres and Tubes for Transportation
of
Dangerous
Goods Commission.
The 20lb. cylinder must have a shut off valve
terminating in a valve outlet specified, as
applicable, for connection type QCCl in the
standard for compressed gas cylinder valve outlet
and inlet connection ANSIICGA-V-1.
The cylinder supply system must be arranged for
vapor withdrawal. The cylinder must include a collar
to protect the cylinder valve.
Manifold pressure: (operating) 10 in. water column
(W.C.), (non-operating) 11.2 in. water column
(W.C.).
The LP gas cylinder must be fitted with an Overfill
Protection Device (OPD).
8
LP GAS HOOK-UP
Make sure the black plastic grommets on the LP
cylinder valve are in place and the hose does not
come into contact with the grease tray or grill head.
CONNECTION
your grill is equipped with gas supply orifices for
use only with liquid propane gas. It is also equipped
with a high capacity hose!regulator
assembly
for
connection to a standard 20lb. LP cylinder
(18-1/4
in. high, 12-1/4 in. diameter).
To connect the LP gas supply cylinder:
1. The tank valve should be in the "OFF" position.
If not, turn the valve clockwise until it stops.
2,
Make sure the tank valve has the proper type 1
external male thread connections
per
ANSIZ21.81.
3.
Make sure the burner valves are in the "OFF"
position.
4.
Inspect the valve connections, port and
regulator assembly. Look for any damage or
debris. Remove debris and inspect the hose for
damage.
.
When connecting
the regulator assembly
to the
valve, use your hand to tighten the nut
clockwise
until it stops. Use of a wrench could
damage the quick coupling nut and result in a
hazardous
situation.
6.
Open the tank valve fully by turning the valve
counterclockwise.
7.
Before lighting the grill, use a soap and water
solution to check all the connections
for leaks.
8.
If a leak is found, turn the tank valve off and do
not use the grill until a local LP gas dealer can
make repairs.
-_ WARNING
I
Never attempt to use damaged or obstructed
lequipment. See your local LP gas dealer for repair.
DISCONNECTION
1. Turn off the burner valves and make sure the
grill is cool.
2.
Turn off the tank valve by turning the control
knob clockwise until it stops.
3.
Detach the regulator assembly from the
tank valve by turning the quick coupling nut
counterclockwise.