ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS
A CAUTION:
For personal
safety, do not
use an extension
cord with this appliance.
Remove house fuse or open circuit
breaker
before beginning
installation.
This appliance
must be supplied with the proper
voltage and frequency,
and connected
to an
individual
properly grounded
branch circuit,
protected
by a circuit breaker or fuse having
amperage
as specified on the rating plate. The
rating plate is located under the cooktop. See
the Lift-Up Cooktop section in this manual for
instructions
on how to lift the cooktop.
Rating Plate
\
We recommend
you have the electrical wiring and
hookup of your range connected
by a qualified
electrician.
After installation,
have the electrician
show you where your main range disconnect
is
located.
Check with your local utilities for electrical
codes
which apply in your area. Failure to wire your oven
according
to governing
codes could result in a
hazardous condition.
If there are no local codes,
your range must be wired and fused to meet the
requirements
of the National Electrical Code, ANSI/
NFPA No. 70- Latest Edition. You can get a copy by
writing:
National Fire Protection
Association
Batterymarch
Park
Quincy, MA 02269
Effective January
i,i996,
the National
Electrical
Code requires that new construction
(not existing)
utilize a 4-conductor
connection
to an electric
range.
ELECTRICAL REQUIREMENTS (cont.)
When installing
an electric
range in new
construction,
follow
Steps 3 and 5 for 4-wire
connection.
You must use a 3-wire, single-phase
A.C. 208Y/120
Volt or 240/120 Volt, 60 hertz electrical
system. If
you connect to aluminum
wiring, properly installed
connectors
approved
for use with aluminum
wiring
must be used.
If the electrical service provided does not meet the
above specifications,
have a licensed electrician
install an approved
outlet.
ALL NEW BRANCH CIRCUIT
INSTALLATIONS, MOBILE
HOMES, RECREATIONAL
VEHICLES AND INSTALLATIONS
WHERE LOCAL CODES DO
NOT ALLOW GROUNDING
THROUGH NEUTRAL, REQUIRE
A 4-CONDUCTOR CORD OR
CONDUIT
Use only a 3-conductor
or a 4-conductor
UL-listed
range cord. These cords may be provided with ring
terminals
on wire and a strain relief device.
A range cord rated at 40 amps with 125/250
minimum
volt range is required. A 50 amp range
cord is not recommended
but if used, it should
be marked for use with nominal lsA '' diameter
connection
openings. Care should be taken
to center the cable and strain relief within the
knockout
hole to keep the edge from damaging
the
cable.
, Because range terminals are not accessible after
range is in position, flexible service conduit or
cord must be used.
NOTE: If conduit is being used, go to Step 3D and
then to Step 6 or 7.
. On some models, a filter capacitor
may be
connected
between the black and white leads on
the junction
block.
17