Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not
the result of defective workmanship
or materials in this appliance.
OCCURRENCE
SOLUTION
Air conditioner will not operate.
Air from unit does not feel cold
enough.
Wall plug disconnected.
Push plug firmly
into
wall outlet.
Plug Current
Device
Tripped.
Press the RESET button.
House
fuse blown
or circuit
breaker
tripped.
Replace
fuse with
time
delay
type
or reset
circuit
breaker.
Control
is OFF. Turn Control
ON and set to desired
setting.
P1 appears
in the display
window.
Drain
water
as described
in Drainage
Section.
Shut off
in Heat
mode.
When
the air outlet
exceeds
158 °F (70 °C), the automatic
heat
protection
engages.
Romove
any blockages
and let appliance
cool down.
Room Temperature
lower
than
the set temperature
(Cool
Mode).
Reset the temperature.
Room Temperature
higher
than
the
set temperature
(Heat
Mode).
Reset the temperature.
Room temperature
below
60°F
(16°C).
Cooling
may not occur
until
room
temperature
rises above
60°F (16°C).
Reset to a lower
temperature.
Compressor
shut-off
by changing
modes.
Wait approximately
3 minutes
and listen
for compressor
to
restart
when
set in the COOL mode.
Air conditioner cooling, but room
is too warm = ice forming
on cooling coil behind decorative
front
Outdoor temperature
below 60 °F (16 °C). To defrost the coil, set FAN ONLY mode.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY
mode.
Temperature
is set too low for night-time
cooling. To defrost the coil, set to FAN ONLY mode. Then,
set temperature
to a higher setting.
Exhaust duct not connected or blocked. See EXHAUSTING HOT AIR Section.
Air conditioner cooling, but room
is too warm = NO ice forming
on
cooling coil behind decorative
front,
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature
is set too high. Set temperature
to a lower setting.
Air directional louvers positioned improperly.
Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture,
etc. - restricts air distribution.
Clear blockage in
front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time to remove "stored heat" from walls, ceiling,
floor and furniture.
Air conditioner turns on and off
rapidly.
Noise when unit is cooling.
Room too cold.
Room Too Hot.
Dirty air filter - air restricted. Clean air filter.
Outside temperature
extremely hot. Set FAN speed to a faster setting to bring air through cooling coils
more frequently.
Air movement sound. This is normal. If too loud, set to lower FAN setting.
Vibraion from uneven floor. Move or support appliance correctly on even surface.
Set temperature
too low. Increase set temperature.
Set temperature
too high. Lower setting.
If These Solutions Fail, (::all 1=800=944=9044