Installation - Frigidaire FRA113PT110 Use & Care Manual

Electrolux
Table of Contents

Advertisement

Installation
Instructions
EXAUSTING
HOT AIR
In the COOLING Mode the appliance must be placed close to a window or
opening so that the warm exhaust air can be ducted outside.
First position unit on a flat floor and make sure there's a minimum
of 12"
clearance around the unit, and is within the vicinity of a single circuit outlet
power source.
1. Take the hose out from back of the unit (Fig. 3).
2. Remove adaptor A from unit by sliding sideways (Fig. 4 ).
3. Extend either side of the hose (Fig. 5) and screw the hose to
adaptor A (Fig. 6).
4. Extend the other side of the hose and screw it to adaptor
B (Fig. 7).
5. Slide the assembly onto unit (Fig. 8).
6. Affix the adaptor B into the window slider kit and seal. (Fig. 9&10)
Vertical
window
Window Slider Kit
iVlinimum:26,6"(67,5cm)
iVlaxmum:48.5"(123cm)
Fig. 9
Horizontal
l
window
Window Slider Kit
iVlinimum:26,6"(67,5cm)
iVlaxmum:48.5"(123cm)
Fig, 10
Take the hose out
Fig. 3
ii Slide
:ig, 4
Extend the side of hose
Fig, 5
Fig, 6
The hose can be extended
from its original length of 15" up to 55", but it is
the best to keep the length to minimum
required. Also make sure that the
hose does not have any sharp bends or sags. (Fig. 11)
Fig. 7
i ii
02009
Electrolux Home Products, Inc.
All rights reserved.