Troubleshooting
If the
grill fails to light:
1.
Turn gas off at source and turn control
knobs to
"OFF". Wait at least 5 minutes
for gas to clear, and
then retry.
2.
If your grill still fails to light,
check the gas supply
and connections.
Ensure gas supply is turned
on
(turn
counterclockwise),
there is gas in the tank,
and
the regulator
is properly
seated
in the tank valve.
3.
Repeat lighting
procedure.
If your grill still
fails to light, turn the gas off at the source,
turn the
control
knobs to "OFF", and check the following:
Check that the end of each burner
tube is properly
located
over each valve orifice.
4.
[]
Obstruction
in Gas Line
Correction-"
Detach regulator
hose assembly.
Do not
smoke!
Open all control
knobs at the same time to
"Hi". Close all burner
control
knobs to "OFF" and
reattach
the regulator
hose assembly
to the grill.
[]
Plugged
Orifice or Burner Tube Obstruction
Correction:
Remove burners
from grill and clean
following
the burner cleaning
instructions
later in this
manual.
Observe
valve orifice
to be sure there
is no
obstruction
visible.
[]
ff an obstruction
is suspected
in Gas Valve or
Manifold,
call the Customer
Support
Center.
[]
Misalignment
of Igniter
and Burner
Correction:
Check for proper
position
of the
electrode
tip. The gap between
the electrode
tip and
burner
should
be approximately
3/16
of an inch.
Adjust
if necessary.
With the gas supply
off and all
control
knobs set to "OFF" press the electric
igniter
button
and check for the presence
of a spark
at the
electrode.
[]
Disconnected
Electric
Wires
Correction:
fnspect
the electronic
igniter
(see
Parts List) found
behind the control
panel.
Connect
loose electric
wires to ignition
assembly.
[]
Weak AA Battery
Correction:
Unscrew
the igniter
cap and replace
the battery.
Do not dispose
of batteries
in fire!
Batteries
may
explode
or leak.
[]
ff the grill still does not light you may need to reset
the flow limiting
valve in your LP tank.
Note:
This
procedure
should
be done every time a new LP gas
tank is connected
to your grill.
Follow
the steps below
to reset
the flow
limiting
device,
[]
Turn LP gas tank valve "OFF".
[]
Disconnect
the regulator
assembly
from LP Gas
tank.
[]
Open all burner
control
knobs to "Hi" at the same
time.
[]
Close all burner
control
knobs to "OFF"
[]
Let the LP Gas tank stand for at least 10 minutes.
[]
Reconnect
the regulator
assembly
to the LP Gas
tank.
[]
Slowly
turn on the LP Gas tank valve.
[]
Follow the burner
lighting
procedures
to light the
burner
farthest
away from the gas source.
Should a FLASHBACK fire occur in or around
the burner
tubes, follow
the instructions
below.
Failure to comply
with these
instructions
could result
in a fire or
explosion
that could cause serious
bodily injury,
death,
or property
damage.
Shut off gas supply
(turn
the LP tank valve
clockwise)
to the gas grill.
Turn the control
knobs to the "OFF" position.
Open the grill lid.
Put out any flame
with a Class B Fire
extinguisher
Once the grill has cooled down,
clean the
burner
tubes and burners
according
to the
cleaning
instructions
in this Operator's
Manual.
Customer
Support
Center
Call 8:30 AN to 5:00 PM CST 1-8OO-933-O527
Monday through
Friday.