These guidelines
should beused b y aqualified
service agent Call Sears Service at1-800-4-MY-HOME
(1-800-469-4663)
forassistance.
Inform t he associate
that t his isa"Flammable
Vapor Ignition Resistant"
Product.
Improperly sealed, hot or cold supply connection,
relief valve, drain valve, or thermostat threads.
Leakage from other appliances
or water lines.
Condensation
of flue products.
Thermal expansion
in closed water system.
Improperly seated valve.
Tighten threaded connections.
WATER LEAKS
Inspect other appliances
near water heater.
Refer to CONDENSATION.
Install thermal expansion tank (DO NOT plug T&P valve).
LEAKING T&P VALVE
Check relief valve for proper operation
(DO NOT plug T&P valve).
High sulfate or mineral content in water supply.
Drain and flush heater thoroughly,
then refill.
SMELLY ODORS
Bacteria in water supply.
Chlorinate or aerate water supply.
Gas control knob not positioned
correctly.
Referto LIGHTING INSTRUCTIONS.
Main gas supply off.
Turn on main gas Shut-off valve.
Igniter tip more than 1/8" from pilot hood.
Adjust igniter tip.
Thermocouple
malfunction.
Replace pilot assembly.
Thermocouple
TCO malfunction.
Replace pilot assembly.
Melted insulation on igniter wire or shorting
Contact Sears Service to determine cause.
PILOT WILL NOT LIGHT
of igniter wire.
High ambient room temperature.
Contact Sears Service to determine cause.
Wire disconnected
from spark igniter.
Reconnect
wire connector to spark igniter.
Broken electrode or electrical wire.
Replace pilot assembly.
Piezo Igniter generator fails to operate or
Replace Piezo Igniter generator.
malfunctions.
Thermocouple
TCO malfunction.
Replace pilot assembly.
High ambient room temperature.
Contact Sears Service to
determine cause.
BURNER WILL NOT
Dirty or clo_l,ged air intake screen.
Clean and reinstall air intake screen.
STAY LIT
Flame arrestor openings blocked.
Contact Sears Service to
determine cause.
Defective Gas Control.
Replace Gas Control.
Dirty pilot burner.
Clean pilot assembly.
Dirty or clogged air intake screen.
Clean and reinstall air intake screen.
PILOT OUTAGE
Thermocouple
tip is not in contact with pilot flame.
Insert thermocouple
correctly.
Thermocouple
malfunction.
Replace pilot assembly.
Thermocouple
TCO malfunction.
Replace pilot assembly.
Defective Gas Control.
Replace Gas Control.
Heater not lit or thermostat not on.
Refer to LIGHTING INSTRUCTIONS.
Thermostat
set too low.
RefertoTEMPERATURE
REGULATION.
Heater undersized.
Reduce hot water use.
NOTENOUGH
Low gas pressure.
Contact your gas supplier.
HOTWATER
Incoming water is unusually cold.
Allow more time for heater to re-heat
Leaking hot water pipes or fixtures.
Have plumber check and repair leaks.
High temperature
limit switch activated.
Contact Sears Service to
determine cause.
WATER TOO HOT
Thermostat
set too high.
Refer toTEMPERATURE
REGULATION,
WATER HEATER SOUNDS
Condensation
dripping on burner.
Refer to CONDENSATION.
SIZZLING
- RUMBLING
Sediment or calcium in bottom of heater tank.
Clean sediment from tank. Refer to DRAINING
instructions
in Maintenance
section of manual.
SOOTING
Improper combustion.
No adjustment available. Contact Sears Service
to determine
cause.
Lack of supply air,
Improperly installed vent piping.
Downdraft,
Poor combustion.
VENTGASODORS
Contact Sears Service to determine cause,
26