Troubleshooting Items - Kenmore 33968 - Power Miser 9 Specification

Gas water heater
Table of Contents

Advertisement

These g uidelines
should b eused b yaqualified service agent. Call S ears S ervice at1-800-4-MY-HOME
<R_
(1-800-469-4663)
forassistance.
Inform the associate
that t his isa"Flammable
Vapor Ignition Resistant"
Product.
WATER
LEAKS
LEAKING T&P VALVE
SMELLY ODORS
PILOT WILL NOT LIGHT
BURNER WILL NOT
STAY LIT
PILOT OUTAGE
NOT ENOUGH
HOT WATER
WATER TOO HOT
WATER HEATER SOUNDS
SIZZLING - RUMBLING
SOOTING
VENT GAS ODORS
Improperly sealed, hot or cold supply connection,
relief valve, drain valve, or thermostat threads.
Leakage from other appliances or water lines.
Condensation
of flue products.
Thermal expansion in closed water system.
Improperly seated valve.
High sulfate or mineral content in water supply.
Bacteria in water supply.
Gas control knob not positioned correctly.
Main gas supply off.
Igniter tip more than 1/8" from pilot hood.
Thermocouple
malfunction.
Thermocouple
TCO malfunction.
Melted insulation on igniter wire or shorting
of igniter wire.
High ambient room temperature.
Wire disconnected
from spark igniter.
Broken electrode or electrical wire.
Piezo Igniter generator fails to operate or
malfunctions.
Thermocouple
TCO malfunction.
High ambient room temperature.
Dirty or clogged air intake screen.
Flame arrestor openings blocked.
Defective Gas Control.
Dirty pilot burner.
Dirty or clogged air intake screen.
Thermocouple
tip is not in contact with pilot flame.
Thermocouple
malfunction.
Thermocouple
TCO malfunction.
Defective Gas Control.
Heater not lit or thermostat not on.
Thermostat
set too low.
Heater undersized.
Low gas pressure.
Incoming water is unusually cold.
Leaking hot water pipes or fixtures.
High temperature limit switch activated.
Thermostat
set too high.
Condensation
dripping on burner.
Sediment or calcium in bottom of heater tank.
Improper combustion.
Lack of supply air.
Improperly installed vent piping.
Downdraft.
Poor combustion.
Tighten threaded connections.
Inspect other appliances
near water heater.
Refer to CONDENSATION.
Install thermal expansion tank (DO NOT plug T&P valve).
Check relief valve for proper operation
(DO NOT plug T&P valve).
Drain and flush heater thoroughly, then refill.
Chlorinate or aerate water supply.
Refer to LIGHTING INSTRUCTIONS.
Turn on main gas shutoff valve.
Adjust igniter tip.
Replace pilot assembly.
Replace pilot assembly.
Contact Sears Service to determine cause.
Contact Sears Service to determine cause.
Reconnect wire connector to spark igniter.
Replace pilot assembly.
Replace Piezo Igniter generator.
Replace pilot assembly.
Contact Sears Service to
determine cause.
Clean and reinstall air intake screen.
Contact Sears Service to
determine cause.
Replace Gas Control.
Clean pilot assembly.
Clean and reinstall air intake screen.
Insert thermocouple
correctly.
Replace pilot assembly.
Replace pilot assembly.
Replace Gas Control.
Refer to LIGHTING INSTRUCTIONS.
Refer to TEMPERATURE
REGULATION.
Reduce hot water use.
Contact your gas supplier.
Allow more time for heater to re-heat.
Have plumber check and repair leaks.
Contac tSears Service to
determine cause.
Refer to TEMPERATURE
REGULATION.
Refer to CONDENSATION.
Clean sediment from tank. Refer to DRAINING
instructions in Maintenance
section of manual.
No adjustment available. Contact Sears Service
to determine cause.
Contact Sears Service to determine cause.
26

Hide quick links:

Advertisement

Table of Contents
loading