Download Print this page
Kenmore Quiet Comfort 758.144150 Owner's Manual

Kenmore Quiet Comfort 758.144150 Owner's Manual

Quiet comfort whole house humidifier 13 gallon output, innovative twin fan technology

Advertisement

Quick Links

H •..... • •
Save this manual
for future
reference
SEAR8
owner's
manuat
Stock No.
42-14415
Model No.
758.144150
FOR YOUR
SAFETY:
READ
ALL INSTRUCTIONS
CAREFULLY
®
QUIET COMFORT
WHOLE HOUSE
HUMiDiFiER
13 Gallon Output
innovative Twin Fan
Technology
• Operating
instructions
......
J
- Parts List
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Part No, SP6354
Printed in Canada

Advertisement

loading

Summary of Contents for Kenmore Quiet Comfort 758.144150

  • Page 1 H •..• • Save this manual for future reference SEAR8 owner's manuat Stock No. 42-14415 Model No. 758.144150 ® QUIET COMFORT WHOLE HOUSE HUMiDiFiER 13 Gallon Output FOR YOUR SAFETY: innovative Twin Fan READ Technology ALL INSTRUCTIONS CAREFULLY • Operating instructions ..
  • Page 2: Table Of Contents

    FULL ONE YEAR WARRANTY ON HUMIDIFIER (1) year fr0m the date of purchase, this humidifier fails due to a defect in material Or workmanshiP, Sears will repair it, free of charge. If within two (2) years from the date of purchase, the motor fails due to defect in material or workmanship, Sears r service ts available...
  • Page 3 Know "Your Humidifi'er ............Control Panel Cover & Pivoting Lid Removed for Clarity Desired Humidity Fan Assembly Controls Fitter Housing Filters: Replacement Filter 42-14415 Description Gaiton OutpuV24 Hrs. 2-3/8 Gallons Each Capacity of Bottles 2700 Sq. Ft. Coverage Fan Speeds Filters Fill Light Desired...
  • Page 4 Ultrasonic humidifiers. Assembly ......Your new Sears Kenmore humidifier is com- owneds manual for proper usage. The pletely assembled for you to use. Remove packaging material is located under the fan the packaging material from •inside your...
  • Page 5: Water Flit

    Location instructions (continued) ....Step 2 NOTE: DL_e to release of coo!, moist The humidifier should be pos_ioned with the from humid_er, it is best to direct air away back (cord exit side), at least 2 inches away from home thermostat &r_d hot air registers.
  • Page 6 Water Fill (continued) Notice the water bottles are designed as right'and left:! hand units.: Position them in _e _correct iocation ;so the humidifier:can function properly. The waterbottles should rest in the front of the cabinet. Each"E-Z- Fill Side:Cap" must be:facing the rear of the unit.
  • Page 7: Humidifier Controls

    Operating Humidifier Controls ..,,, The operating controls of your Kenmore Fill Light Quiet Comfort whole house humidifier are When the humidifier is almost out of water, located on the top center of the humidifier. the Fill light will come on and the fans will The controls are found under the smoked automatically shut off.
  • Page 8: Operating -13Ps For Best Performance

    ::::4 _:i:i ¸ :• •i /!:,/ •= • • Step 4 if humidifier stops running and the "Desired Humidity" indicator is illuminated, humidity level is at the normal require- ments for that setting or it is adjusting to home conditions• The chart below shows recommended...
  • Page 9 42-14911. I Ail filters may be rinsed in clear water only. Take care not to damage paper. To replace evaporative wicking filters in your Kenmore Quiet Comfort Whole House humidifier, fol- low the instructions below. 1. Unplug humidifier and proceed to clean.
  • Page 10: And Care Of Filters

    Replacement and Care of Filters (continued) Install new filters in the filter housing track with the glue beads of the wick- ing pad to the inside of the filter hous- Fixed Tabs ing. Spring Tabs Return the top cover of the filter housing by installing the cover over the fixed tabs on the rear of the lower Fiker...
  • Page 11: Your Humidifier

    Cleaning Your Humidifier _lllji ....: ..WARNING: To reduce the risk Step 2 injury, fire or damage to humidifier, To Remove Parts ,use only cleaners specifically rec- a. Open the pivoting lid and remove water ommended for humidifiers. Never bottles and set aside. Grasp the fan use flammable, combustible or poi-...
  • Page 12 Cleaning of Humidifier (continued) ..= B_:,Weekly Maintenance End of Season Removing Scale: Fo low "B-Weekly MaintenanCe ;_'I Fili:the i_umidffier cabinet with one 8 instructions at end of humidification: oz_ cupof undiluted white vinegar. Let season. lution stay 20 minutes. 2.
  • Page 13 Troubleshooting ..:...." ' ,'iTrouble ....Probable Cause= , .." Remedy Unit will not run and neither • No Power. • Check 120 volt power source. control panel tight is illuminated, - Float retainer is positioned - Slide float retainer down to Unit will not shut off.
  • Page 14: Repair Parts

    Repair Parts Parts List for Sears Humidifiers ..Model No. 758.144150...
  • Page 15 Repair Parts ........Parts List for Sears Humidifiers Model No. 758.144150 Always order by part number - Not by key number >.-I r- _j "o _-___ > -_ _-_-_._ LIJl_ g==. o- I. '_ g,o _ OOr_o_O09 U-_OOg_LL COOtr _-NmmmNm "o >.
  • Page 16 Forthe repair or replacementpartsyou need Call7 am- 7 pm, 7 days a week 1oS@O-366°PART (1-800-388-7278) For in-home majorbrand repair service Call24 hours a day, 7 days a week t-SGOo4-R_PAmR (1-800-473-7247) Forthe Bocationof a Sears RepairService Center in your area Call24 hours a day, 7 days a week t -800-488-1222 For informationonpurchasinga Sears MaintenanceAgreementor to inquire...