Electronic control

Advertisement

Available languages

Available languages

Fig. #
3
¢ontrom Panel
Fig. # 4
¢ontrom
Once the function mode is decided you wiHI have to set the fan speed_ If
you choose the A/C mode you can run the fan in one of the 3 speeds Hi,
Med., Lo or in the Aub speed, mnthe Auto speed the fan wiHIstart at High,
Med or Lo as the temperature varies in the room.
Tr: temperature inside the room.
Ts: the set temperature.
When Tr >Ts+2°F, the Hi is to be automatically.
When Tr<Ts, the Lo is to be
set. When Ts<Tr_<Ts+2°F, t he Med is to be set. Once the set temperature in
the room is reached the Auto fan setting wilH have the fan running on Lo.
]_ takes 3 minutes to switch the fan speed, (See Fig # 4)