Hot Oven
Restart
if you
turn off the oven but then decide
to turn it back on before
it has cooled
to room
temperature,
the burner may not light properly
'l'his is due to the thermostat
still sensing
a heated
oven and not allowing
the maximmn
gas flow rate into the burner
Press in and
turn the oven
control
knob counter
clockwise
all the way to the ' BROIL"
position
to
relight
the burner.
After
the burner
has ignited,
you may adjust
the oven control
to the
desired
temperature
if tile oven burner
does not ignite and maintain
the flame,
one of the following
situations
may have occurred
1
The pilot burner
has _one out.
Relight
the oven pilot
2
The pilot will not keep
the flalne safe_"
probe
heated.
Adjust
the size of the pilot
flame
Or, tile thermocouple
connection
at tile thermostat
may need to be tightened
3
The flame
safety
probe
nlay
not be properly
located.
Locate
the probe directly
over the pilot burner
On spark
ignition
ovens,
tile end of tile flame
safety probe
must ve15" close to tile side of tile burner
right in front of tile flame ports
4
The burner
is not ill its proper
position.
Make sure the rear of tile burner is seated
on the iNector
elbo_x and tile front is bolted onto the burner support
5
The spark
i_.,mitor is defective.
Contact
an authorized
service
technician
6
The ghm
bar ignitor
is defective.
Contact
an authorized
service technician
6. Oven Burner
Air Shutter
Adjustlnent
i'he
oven
burner
flame
should
be a clean,
blue
flame
with
distinct
inner
cones
approximately
" long
A soil, lazy flame
with indistinct
cones means
too much
gas or
not enough
air.
A noisy lilting
flame means
too much
air
if adjustments
are necessary
you must first loosen
tile lock screw located
at tile top of tile air shutter, then rotate the air
shutter to correct
setting,
and retighten
screw
OVEN BURNER
LOCK SCREW
AIR SHUTTER
ORIFICE_
OVEN SAFETY VALVE
OVEN BURNER
Oven burner flame can be checked
as follows
(xxithout burner
baflle in place):
• fo correct
a yellow flame-increase
size of air shutter opening.
• fo correct
a lifting, but distinct,
blue flame-Decrease
size of air shutter opening
fhe air shutter
should
be set approximately
2/3 open for natural
gas, and approximately
l\fll open on LP (Propane)
gas
19

Advertisement

loading