Available languages

About the water softener sgstem.
Breaking
a Salt Bridge
Sometimes, a hard crust or salt bridge forms in
the salt storage area. It is usuallu caused bu high
humidity or the wrong kind of salt. When the salt
bridges, an empt U space forms between the
water and salt. Then salt will not dissolve in the
water to make brine.
If the brine tank is full of salt, it is hard to tell
if Uou have a salt bridge. Salt is loose on top, but
the bridge is under it. The following is the best
wag to check for a salt bridge.
Salt should be loose all the wag to the bottom of
the tank. Take a broom handle or like tool, and
carefullu push it down into the salt, working it up
and down. If the tool strikes a hard object (be
sure it's not the bottom or sides of the tank), it's
most likelu a salt bridge. Carefullu break the
bridge with the tool. Do not pound on the walls
of the tank.
If the wrong kind of salt made the bridge, take it
out. Then fill the tank with nugget or pellet salt
only. In humid areas, itis best to fill with less salt,
more often to prevent a salt bridge from forming.
Pencil
mark
Broom
handle
Push tool into salt
bridge to break
/
Water
level
bridge
14
Cleaning the Nozzle and Venturi Assemblg
A clean nozzle and venturi is needed for the
water softening system to work properly. This
small unit makes the suction to move brine from
the salt storage area to the resin tank during
recharge. If it becomes plugged with sand, dirt,
etc., the water softening sustem will not work
and Uou will get hard water.
To get to the nozzle and venturi, remove the
water softening sustem top cover. Be sure the
water softening sustem is in service cgcle (no
water pressure at nozzle and venturi). Then, while
holding the nozzle and venturi housing with one
hand, remove the cap. Lift out the screen support
and screen, then the nozzle and venturi. Wash
and rinse the parts in warm water until clean. If
needed, use a small brush to remove iron or dirt.
Also check and clean the gasket.
NOTE; Some models have a small flow plug
located in the nozzle and venturi, and/or a small
cone shaped screen in the housing. Be sure to
check and clean these parts, if uour model is
so equipped.
Carefullu replace all parts in the correct
ordeE Lightlu lubricate the o-ring seal with clean
silicone grease or petroleum jellu and place in
position. Install and tighten the cap, by hand
only. Do not overtighten
the cap.
Cap -_
O-ring seal _0
Screen
--_._
@
support
Screen
*Flow plug _
i
Nozzle
& __
_
Screen
Venturi
_
_--
Gasket _v=_
*Flow -_l__
plug
Nozzle &
Venturi
housing
IMPORTANT:
Be sure smoll holes in the gasket are
centered
directlg
over the small holes in the nozzle and
venturi
housing.
*Install with numbered
side up, concove
side down.