GE GXSF30H Owner's Manual & Installation Instructions page 22

Water softening system
Table of Contents

Advertisement

Available languages

Available languages

Before you call for service...
Troubleshooting Tips
Problem
Possible Causes
What To Do
Salty tasting or
Unit not sanitized
* Complete the Sanitization Procedureson page 12.
brown/yellow colored
• At completion of recharge cucle (approx. 2 hrs),run water
water after installation
from faucets to purge the salty water.
Low water pressure
Check pressure.
• Drain height 8' or less,pressureshould be minimum of 20 psi.
• Drain height above 8', pressure should be minimum of 50 psi.
Restricted drain hose
• Clean and reconnect hose.
• Check for kinksin drain line.
Brown/yellow
Unit was idle for a period of time
• Complete the Sonitizotion Procedureson page 12.
colored water
Resin beads showing
Cracked distributor
• Call for service,
up in drinking water
and sink
Sounds gou might hear
Running water from the unit
• This is normal.
into a drain during recharge
Water has air bubbles
Air in sgstem after installation
• Will go away after it runs for a while.
and is cloudy
Error Code on control
Wiring mag have worked loose
• See page 16 for details.
in the control
• Unplug transformer,
• Remove control cover,release clips on side.
• Checkfor loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.
• Reassemble control cover.
• Plug in Transformer,
• Wait six minutes for Error Codeto reappear,
• If Error Code reappears, call for service.
22