Download Print this page

Monogram ZICS360NRFRH Owner's Manual page 17

Bottom-freezer built-in refrigerators

Advertisement

Performance Data Sheet
SmartWaterFiltrationSystem
MWF Cartridge
s system has been tested according to NSF/ANS142,/53 for reduction of the substances listed below.
; concentration of the indicated substances in water entering the system was reduced to a concentration
.
s than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142J53.*
0% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
rameter
USEPA
lnflu_tt
Influent
Efflue_at
MCL
I_lle%,e
Concentration
Averab, e
Averab, e
Maximum
lofine
--
2.0 mg/L + 10%
1.96mg/L
0.06mg/L
0.11mg/L
? _,c O
.....
L "tictdate**
--
_> 10,000particles/mL
6,400,000#/mL
58,833#/mL
150,000#/mL
% Reduction
Average
Minimum
96.77%
94.74%
99.14%
97.97%
Mi..a_q_t_a
Reduction
> 50%
_> 83%
Standard No. 53: Health Effects
ameter
idity
++SLOS
aatpH65
.dat pH8.5
_uty at pH 6.5
rcury at pH 8.5
chlor
dane
,D
' _aphene
; B_j3Z_2[Ie
r
?oofuran
1, 4 dichlorobenzene
azlne
USEPA
MCL
0.5 NTU
_> 99,95% Reduction
_> 99% Reducdon
0.015 mg/L
0.015 mg/L
0,002 mg/L
0.092 mg/L
0.002 mg/L
0.0002 mg/L
0.070 nag/L
0.003 nag/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
0.003 mg/L
Intluent
I_aallen_
Concmatration
11 + 1NTU***
Minimum 50,000 L
107to 10s fibers/L; > 101an
0.15 rag/L+
10%
0.15 nag/L+ 10%
0,006 mg/L + 10%
0.006 mg/L _+ 10%
0.04 mg/L +_ 10%
0.002 nag/L+_ 10%
0.210 mg/L +_ 10%
0.015 nag/L+_ 10%
0.015 rag/L_+ 10%
0.080 mg/L _+10%
0.225 mg/L _+10%
0.009 rag/L4.10%
Intlue_t
Average
10.5NTU
118,750#/L
57 MF/L
0.1567nag/L
0.1433nag/L
0.0059mg/L
0.0057mg/L
0.0367mg/L
0.0020mg/L
0.2033mg/L
0.0160mg/L
0.0145mg/L
0.0830mg/L
0.2283mg/L
0.0087nag/L
EP_uellt
Average
Maximum
0.14 NTU
0.28NTU
<I#/L
4#/L
0.996 MF/L
< 1 MF/L
<0.0Olmg/L
<0.001 mg/L
<0.001 mg/L
<0.001 rng/L
0.000350mg/L
0.0007 mg/L
0.000325mg/L
0.0006 nag/L
0.00023nag/L
0.0004 nag/L
<0.00002rng/L ."0.00002mg/L
0.00337mg/L
).011000mg/L
0.00100nag/L 3.001000mg/L
0.000500mg/L 3.000500 nag/L
0.001000mg/L 3.001000 mg/L
0.000500mg/L 3.000500 nag/L
<0.0005mg/L
<0,0005mg/L
% Reduction
Avera_
Minimum
98,54%
97.20%
> 99.99%
> 99.99%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
96,51%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93.33%
MAn. R equired
Reduction
0.5 NTU
>99.95%
_>99%
0.010 nag/L
0.010 nag/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 nag/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.04 nag/L
0.075nag/L
0.003nag/L
_' _tedusinga flow rateof O.50 gpm;pressure of OO psig;pHof 7.5+_ 0.5;temp,of 68°_+ 5°F120° _ 3°C)
. 4easurement in Particles/mL Particles usedwere0.5-1microns
• '_rqTU=Nephelometric Turbidity unts
:rating
Specifications
....;_pacity: certified
for up to 300 gallons
(1135 1) up to six months
for models without
a replacement
filter indicator
light;
to one year for models
wath a replacement
filter mthcator
hght
"essure
requirement:
40-120
psi (2.8--8.2 bar),
non-shock
: .zmperature:
33-100°F
(0.6-38°C)
!ow rate: 0.5 gpm
(1.9 lpm)
_eral Installation/Operation/Maintenance
Requirements
: tush new cartridge
at full flow for 3 minutes
to purge
out trapped
air.
;_eplace cartridge
when
the indicator
light flashes
or water flow rate is reduced
on non-indicator
units.
_cial Notices
_ _i_stallation
instructions,
parts and service availability,
and standard
warranty are included
with the product when
shipped.
'.! This drinking water system must be maintained
according to manufacturer's
instructions,
including
replacement
of filter cartridges.
i,Oo
not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before or
: after the system. Systems certified
for cyst reduction
may be used on disinfected
water that may contain
filterable
cysts.
,11. 7he
contaminants
or other substances
removed
or reduced
by this water treatment
system are not necessarily
in your water.
:l _heck for compliance
with the state and local laws and regulations.
' tote that while the testing
was performed
under standard laboratory
conditions,
actual performance
may vary. Systems must be
'1stalled
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
• tern Tested
and Certified
by NSF International
against
ANSI/NSF
Standard
42 & 58 for the reduction
of:
-,_, d ard No. 42: Aesthetic
Effects
-7?emical Unit
':_,hlorlne Taste and Odor
":: _%hanical
Filtration Unit
;2Particulate
Reduction,
ClassI
51
Standard
No. 53: Health
Effects
Chemical
Reducdon
Unit
Alachlor
and Au-azine
Reduction
Benzene
and Carbofuran
Reduction
1,4 dichlorobenzene
and 2,4-D Reduction
Lead and Lindane
Reduction
Mercury
and Toxaphene
Reduction
Mechanical
Filtration
Unit
Turbidity
Reduction
Cyst and Asbestos
Reduction
17
' [ufactured
for: General
Electric
Company,
Louisville,
KY 40225
EST. No. 070595-MN-001
17.