GE PGP989 Owner's Manual & Installation Instructions page 29

Gas downdraft cooktop
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
ELECTRICALCONNECTIONS
1_] ELECTRICAL REQUIREMENTS
120-volt, 60-Hertz, properly grounded branch circuit
protected by a 15-amp or 20-amp circuit breaker or
time-delay fuse.
EXTENSION CORD CAUTIONS
Because of potential safety hazards associated with
certain conditions, we strongly recommend against the
use of an extension cord. However, if you still elect to
use an extension cord, it is absolutely necessary that
it be a UL-listed, B-wire grounding-type
appliance
extension cord and that the current carrying rating of
the cord in amperes be equivalent to, or greater than,
the branch circuit rating.
GROUNDING
IN PORTANT
-- (Please reed
carefullg.)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
Preferred Method
xsts
The power cord of this appliance
is equipped
with
a three-prong
(grounding) plug which mates with
a standard
three-prong
grounding
wall receptacle
to minimize the possibility of electric shock hazard
from this appliance.
The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD.
An adapter may be used only on a 15-amp circuit.
Do not use an adapter
on a 20-amp circuit. Where
local codes permit, a TEMPORARY CONNECTION
may be made to a properly grounded
two-prong
wall receptacle
by the use of a UL-listed adapter,
available
at most hardware
stores. The larger slot
in the adapter
must be aligned with the larger slot
in the wall receptacle
to provide proper polarity
in the connection
of the power cord.
Temporarg
Method
_
(Adapter plugs not permitted
II
___'_
_ }
inCanada)
II _
J J
Alignlargeprongs/slots __)
II -_
I I
i i _)e°oPnergrt_ und
CAUTION:
Attaching
the adapter
ground terminal to the wall receptacle
cover
screw does not ground the appliance
unless the
cover screw is metal, not insulated, and the wall
receptacle
is grounded through
the house
wiring. The customer
should have the circuit
checked by a qualified
electrician
to make sure
the receptacle
is properly grounded.
When disconnecting
the power cord from the
adapter, always hold the adapter with one hand.
If this is not done, the adapter ground terminal
is
very likely to break with repeated
use. Should this
happen, DO NOT USE the appliance
until a proper
ground has again been established.
29