Installation
Instructions
LOCATION OF YOUR DRYER (cont.)
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
• Your dryer is approved
for installation
in an
alcove or closet, as stated on a label on the
dryer back.
• The dryer MUST be vented to the outdoors.
See the EXHAUST INFORMATION section.
° Minimum
clearance
between dryer cabinet and
adjacent walls or other surfaces is:
0" either side
3" front and rear
• Minimum vertical
space from floor to overhead
shelves, cabinets, ceilings, etc., is 52".
• Closet doors must be Iouvered or otherwise
ventilated
and have at least 60 square inches
of open area equally distributed.
If the closet
contains
both a washer and a dryer, doors must
contain a minimum
of 120 square inches of open
area equally distributed.
• No other fuel-burning
appliance
shall be
installed in the same closet with the dryer
(gas models only).
BATHROOM OR BEDROOM
INSTALLATION
• The dryer MUST be vented to the outdoors.
See EXHAUST INFORMATION.
• The installation
must conform
with local codes or,
in the absence of local codes, with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric
dryers) or NATIONAL FUEL GAS CODE, ANSI Z223
(for gas dryers).
16