Electrical requirements.
Read these instructions
completely and carefully.
ElectricalConnection Informationfor ElectricDryers
WARNING--To reduce the risk of fire,
elecu'ic shock, or personal
injm7:
• DONOT USEAN EXTENSIONCORDWITH THIS
APPLIANCE.
• THISAPPLIANCEMUST BE PROPERLY GROUNDED.
Electrical Requirements
• This dxyer
must
be connected
to an individual
branch
circuit, protected
by the required
time-
delay fllses or circuit breakers.
208V or 240V
installation
30 amps.
Thisdryermustbe electrically groundedin
accordance with local codes and ordinances,or in
the absenceof local codes,in accordance with the
NATIONALELECTRICAL C ODE,ANSI/NFPANO. 70.
• Use copper
conductors
only.
• If the electric supply does not meet the above
specifications,
call a licensed electrician.
NOTE:A wiring diagram is located inside the
control panel.
ElectricalConnection Informationfor GasDryers
WARNING--To reduce tile risk of fire,
electric shock, or personal
injmy:
• DO NOT USEAN EXTENSIONCORDORAN
ADAPTERPLUG WITH THISAPPLIANCE.
• DO NOT UNDERANY CIRCUMSTANCES, CUTOR
REMOVETHETHIRDGROUNDING PRONGFROM
THEPOWERCORD.
Thisdryermust be electrically groundedin
accordance with local codes and ordinances,or in
the absence of local codes, in accordance with the
NATIONALELECTRICAL C ODE,ANSI/NFPANO. 70.
Electrical Requirements
This dUeT must be supplied
with 120V, 60 Hz,
and connected
to an individual
properly
grounded
brand circuit, protected
by a 15 or
20 amp circuit breaker or time-delay
fuse.
If the electric supply provided
does not
meet the above specifications,
it is
recommended
that a licensed elecu'ician
install an approved
outlet.
External Ground(if required)
An external groundwire, (notprovided),which
meets local codes,may be addedby attaching it to
the green groundscrew on the rear of the dryer in
the upper left hand corner,and to groundedmetal
cold water pipe or otherestablished ground.
........................
Attachgroundwire
,v
_+)
Io to, oc l
]
NOTE:A wiring diagram is located inside the
control panel.