Performance Data Sheet
GESmartWater Filtration System
GWF Cartridge
Health Claim Performance
Certified
by NSF/ANSI*
'100% safety
factors
built in for unmetered
usage)
Standard
No. 42: Aesthetic
Effects
PaJ:mneter
Chhmue
T&O
Particulate**
Parameter
USEPA
MCL
USEPA
Tudfidiw
Cysts
I,ead at pH 6.5
I,ead at pH 8.5
Lindane
Mrazine
2,4-D
._sbestos
hlfluent
Challenge
1.9 ppm
200,000
Effluent
Average
0.02 ppm
3,978
StaaldaJ:d No. 53: Health
Effects
hlfluent
Effluent
Ma_xinluin
0.05ppm
7,800
% Reduction
Average
Minimum
98.90%
97.37%
98.00%
96.10%
% Reduction
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
O.O002ppm
0.003 ppm
0.100 ppm
99%
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0.272 ppm
690 MFI,/ml
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.0000:5 ppm
0.002 ppm
0.042 ppm
0.32 MFI,/ml
Testedusing a flow rate of 0.5 gpm; pressure of 120 psig; pH of ZS+_O.& t emp. of 20+-2.5 C
** Measurement in particles/ml
*** NTU= Nephelometric Units
Ma.,_num
0.1 NTU
55
1 ppb
4.3 i)pb
0.00005 ppm
0.003 ppm
0.090 ppm
1.2 MFI,/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
84.89%
99.95%
Minimum
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Operating Specifications
Capacity:
certified
ti)r up to ,300 ,galh)ns; up to one year
P re s s tlre re q tli re In e u t: 40-120 p s i ( 2.8-8.2 b a r), n o n-s h o c k
::: Temperature:
33-100 F (0.6-38
C)
?Flow
rate: 0.5 gpm
(1.9 lpm)
General Installation/Operation/Maintenance
Requirements
Flush new cartridge
at full flow for 3 minutes
to pm'ge
out trapped
air.
Replace
cartridge
when
flow becomes
too slow.
Special
Notices
Installation
instructions;
parts and service axailabilit};
and standard
_armnt}
are included
_dth the product
_hen
shipped.
This drinking
water
s}stem must
be maintained
according
to mantfl'acttu'er's
instructions,
including
replacement
of
filter
cartridges.
Do not use with water
that is microbiologicall,x
tmsafe
or of tmknown
quality
without
adequate
disinfection
before
or atter
the sxstem.
Sxstems
certified
for c_st reduction
max be used on disiutected
water
that may contain
filterable
cysts.
The contaminants
or other
substauces
remoxed
or reduced
b} this water treatment
s}stem are uot necessaril}
in }our water
Check
for compliance
with the state and local laws and
regulations.
System T(sted and Certified
by NSF Internalional
againsl ANSIiNSF
Standard
42 & 53 fk_r the reduction
of"
Stmldard
No.
42: Aesflmtic
Effects
Chemical
l Jnit
'Ihste
and
Odor
Reduction
Chlorine
Reduction,
Class I
Mechanical
Fihration
Lnit
Particulate
Reduction,
Class
I
Standard
No. 53: Health
Effects
Chemical
Reduction
[ 7nit
Lead
and
Atrazine
Reduction
I_indane
and 2,4-1) Reduction
Mechanical
Fihration
Lnit
'Ihrbiditv
Reduction
Cyst and
A_bestos
Reduction
Manufi_ctm'ed
fiw: (;eneral
Electric Company
I,ouisville
KY40225
17