All internal wiring is factory mounted.
The thermostat which controls the DHW temperature (1,
fig. 10) is adjustable between 20 and 65 °C. The built in
safety thermal cut out operates at 90 °C. Should the
thermal cut out be brought into operation, the
motorized 2 port valve will be operated and shut the
primary flow to the cylinder. Press the reset button (2,
fig. 10) to reset thermal cut out and motorised valve.
Important:
Before resetting the thermal cutout or changing
the temperatur setting of the thermostat, set
the electrical supply off.
Connections to wiring box
•
Provide a wiring box adjacent to the cylinder to make
the electrical connections.
•
Connect the boiler terminals to the corresponding
terminals of the wiring box.
•
Connect the uniSTOR cylinder controls to the wiring
box as shown in figure 10.
5.4.5.3 Connection details for control systems utilising 2 x 2 port motorised valves via external
wiring box
Diagram only applies to the specific controls mentioned
3 amp fused
main supply
L
N
L
N
uniSTOR Cylinder
E
EARTH
Hot water 2 port motorised valve
Fig. 11 Connection details for control systems utilising 2 port motorised valve
uniSTOR GB
ecoTEC
terminal strip
E
L
N
L
N
External wiring box
(Do not use pre-wired printed circuit board type)
N
L
3
N
L
7
10
E
1
2
3
E
5
10
3
BLUE
BROWN
GREY
ORANGE
•
Connect the 2 port valve flying lead to the terminals
of the wiring box.
•
Connect the terminals of the programmer and room
thermostat to the terminals of the wiring box.
•
Connect a 3 amp fused mains supply to the terminals
of the wiring box.
Note:
All wiring must be carried out in accordance with
BS 7671: Requirements for electrical installations
(IEE Wiring Regulations, 16th edition).
•
Check that the sensors from the immersion heater
and the cylinder are positioned correctly in the tubes.
Note:
A special accessory is offered for the electrical
connections between the uniSTOR and an
ecoEURO appliance (No. 307 215).
Programmer
for programmer connections see fig. 16.d
3
4
5
3
4
5
4
5
6
7
8
9
not used
Room thermostat
Vaillant VRT 9090
ACL Drayton Digistat 2, 3, 4
ACL Drayton RTS 1, 2
Danfoss Randall RX-1
Danfoss Randall RMT 230
Danfoss Randall RET 230
Tower SS
Honeywell T6360
Horstmann HRT 1
Siemens-Landys & Staefa RAD 1
Sunvic TLX 2000 series
4
E
5
EARTH
BLUE
Central heating 2 port motorised valve
Installation 5
CENTRAL
HOT
HOT
N
L
HEATING
WATER
WATER
ON
ON
OFF
5
3
6
7
8
10
5
9
6
L
N
E
E
C
A
3
1
N
3
L
3
2
C
B
4
2
1
N
3
L
4
2
1
E
2
3
1
4
2
1
E
2
1
E
4
1
3
E
9
3
4
BROWN
GREY
ORANGE
17