2 Technical data

2 Technical data
Size
Maximum water supply pressure
Operating pressure
Pressure reducing valve
Expansion relief valve
Expansion vessel charge pressure
T/P valve
Net weight
Weight (full)
Height
Cylinder connections:
Cold mains inlet
DHW outlet
Balanced pressure cold water outlet
Secondary return
Primary flow
Primary return
Electrical connections:
3 kW Immersion heater
(according ENBS 60335)
Length of Immersion heater
Three port valve
Cylinder thermostat
Coil Specifications:
Heat loss
Heat up time
Recovery
Note:
Heat up time based on a primary flow rate of
15 l/min at 80 °C.
Temperature rise is from 15 °C to 65 °C.
4
VIH GB 125 S VIH GB 155 S VIH GB 180 S VIH GB 210 S VIH GB 260 S VIH GB 310 S
125
155
28
30
145
175
969
1179
1.4
1.7
21
23
18
18.5
180
210
10
3.5
3.5
6.0
4.0
95 / 7.0
33
39
205
245
1339
1499
22 mm compression
22 mm compression
22 mm compression
G 3 / 4
22 mm compression
(on 2 port valve)
22 mm compression
230/240 V, 50 Hz
430
230/240 V, 50 Hz
230/240 V, 50 Hz
1.8
1.9
24
27
19
22
260
310
44
49
310
340
1789
2109
2.1
2.4
35
47
30
42
uniSTOR GB
Unit
litres
bar
bar
bar
bar
bar
°C/bar
kg
kg
mm
mm
kW/24h
min
min