Mounting Options; Maintenance; Safety Considerations; Desktop Control - Genelec 6010A Quick Setup Manual

Hide thumbs Also See for 6010A:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Desktop Control

The "Desktop" low frequency control (switch
3) attenuates the bass frequencies around
200 Hz by 4 dB. This feature is designed to com-
pensate for the boost often occurring in this fre-
quency range when there is a table or similar
horizontal surface between the listener and the
loudspeaker.

Mounting options

The 6010A offers several mounting options: The
Iso-Pod™ (Isolation Positioner/Decoupler™) vi-
bration insulating table stand allows tilting the
loudspeaker for correct alignment of the acous-
tic axis. A rigid wall bracket provided with the
6010A allows suspending the loudspeaker on
a wall in two different angles. On the rear of the
loudspeaker is a 3/8" UNC threaded hole com-
patible with standard microphone stands and
a wide range of Genelec accessories. On the
rear there are also three pairs of threaded holes
compatible with Omnimount
brackets. For a full list of available options, please
consult Genelec's accessories catalogue at www.
genelec.com or contact your Genelec dealer.

Maintenance

No user serviceable parts are to be found within
the amplifier unit. Any maintenance or repair of the
6010A unit should only be undertaken by qualified
service personnel.

Safety considerations

Although the 6010A has been designed in accord-
ance with international safety standards, the fol-
lowing warnings and cautions should be observed
to ensure safe operation and to maintain the loud-
speaker under safe operating conditions:
4 English
, VESA and Sanus
®
Servicing and adjustment must only be
performed by qualified service personnel. The
loudspeaker must not be opened.
Do not expose the loudspeaker to water or
moisture. Do not place any objects filled with
liquid, such as vases on the loudspeaker or
near it.
This loudspeaker is capable of producing sound
pressure levels in excess of 85 dB, which may
cause permanent hearing damage.
Free flow of air behind the loudspeaker is
necessary to maintain sufficient cooling. Do not
obstruct airflow around the loudspeaker.
Note that the amplifier is not completely
disconnected from the AC mains service unless
the mains power cord is removed from the
amplifier or the mains outlet.
Guarantee
This product is guaranteed for a period of two years
against faults in materials or workmanship. Refer to
supplier for full sales and guarantee terms.
EC DECLArATIoN oF CoNForMITy
This is to certify that the Genelec Monitoring System
6010A conforms to the following standards:
Safety: EN 60065: 2002 + A1:2006 / IEC 60065:2001
7th Edition + A1: 2005
EMC:
EN 55020 A2: 2008
EN 55013: (2001)+ A1 : 2003 + A2: 2009
EN 61000-3-2: 2006
EN 61000-3-3 A2: 2005
The product herewith complies with the requirements
of The Low Voltage Directive 2006/95/EC and EMC
Directive 2004/108/EC
Signed:
Ilpo Martikainen
Chairman of the Board
12-January-2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents