Eurocave INOA 25 Operating And Installation Manual

Eurocave INOA 25 Operating And Installation Manual

Cellar conditioners

Advertisement

Operating and installation instructions - INOA cellar conditioners
March 2009
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INOA 25 and is the answer not in the manual?

Questions and answers

john Trumbetti
May 9, 2025

can I buy a remote control for a iona25 unit and does it have to be programed to that specific unit?

1 comments:
Mr. Anderson
May 19, 2025

Yes, you can get a remote control for the Eurocave INOA 25 unit. Each remote control has a personalized code matched to the conditioner, so it needs to be programmed specifically for that unit.

This answer is automatically generated

john Trumbetti
May 9, 2025

remote control

1 comments:
Mr. Anderson
May 19, 2025

The remote control for the Eurocave INOA 25 has the following features:

- Radio frequency control (433.92 MHz) with a personalized code matched to the unit
- Powered by 2 x 3V CR2430 batteries (one active, one spare)
- On/off indicator
- Temperature and setting display
- Temperature unit indicator (based on country)
- Low battery indicator
- Adjustment keys and a confirmation/on-off key
- Can be installed inside or outside the cellar
- Requires an external sensor for outside installation
- Can switch between internal (IN) and external (OUT) modes through reprogramming
- Designed to be mounted near bottles but away from cold air flow when installed inside the cellar

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Eurocave INOA 25

  • Page 1 Operating and installation instructions - INOA cellar conditioners March 2009...
  • Page 2: Table Of Contents

    ONTENTS WELCOME TO THE WORLD OF EUROCAVE 1 • CONDITIONER DESCRIPTION 2 • IMPORTANT SAFETY RECOMMENDATIONS 3 • ELECTRICAL POWER SUPPLY 4 • CARE FOR THE ENVIRONMENT AND ENERGY SAVING 5 • TECHNICAL SPECIFICATIONS 6 • CELLAR INSULATION 7 • INSTALLING YOUR CONDITIONER...
  • Page 3 Des solutions adaptées à tous vos besoins - Solutions to meet all your needs All Ihren Bedürfnissen angepaßte Lösungen - Soluciones adaptadas a todas sus necesidades EIN K LIMASC HRÄN K E O rigine C uir - Leather - Leder - C uero YST ÈMES DE EGALSYST EME Modulothèque...
  • Page 4: Welcome To The World Of Eurocave

    ELCOME TO THE O ur greatest wish is to accompany your enthusiasm for wine throughout the years… To do so, EuroC ave puts all of its know-how into action to bring together the essential factors in optimal wine maturing: Temperature: T he two worst enemies of your wine are extreme temperatures and sudden uctuations in temperature.
  • Page 5: Conditioner Description

    1 - C ONDITIONER DESCRIPTION HOT AIR Conditioner / ceiling distance: 200 mm min. Ceiling Cellar wall Metal mounting frame Flexible ducting Aesthetic front panel Grid, to be cleaned regularly (see p.11) Mounting frame / conditioner seal Evaporator, to be cleaned regularly COLD AIR 10 - Condenser, to be cleaned regularly...
  • Page 6: Important Safety Recommendations

    2 - I MPORTANT SAFETY RECOMMENDATIONS Warning N ever use your conditioner for anything other than its speci c purpose as described in this guide. W hen using your conditioner, you N ever unplug the conditioner by pulling on the supply lead. Take a rm hold on the plug and pull out smoothly in a should always obser ve certain straight line from the wall socket.
  • Page 7: Technical Specifications

    The Inoa come as standard with the hot air discharge opposite the cold air exit. It can be ordered with the hot air exit on the left or the right side as an option. EuroCave Inoa 25 Cellar conditioner Dimension W385 x D322 x H1250 mm Weight: 43 KG...
  • Page 8: Cellar Insulation

    2 - T ECHNICAL SPECIFICATIONS Dimensions Power Sample in mm supply volume m Inoa 25 W385 x D322 230 V up to x H1250 / 50 Hz 25 m W385 x D322 230 V up to Inoa 50 x H1250...
  • Page 9: Installing The Conditioner

    - The exterior of the conditioner must not be located in an area subject to atmospheric exposure. - No heat-producing appliance must be located in the area to be conditioned (e.g. refrigerator, radiator, boiler). - Do not obstruct the air entry and exit points.
  • Page 10: Ii- Drilling The Wall

    7 - I NSTALLING THE CONDITIONER • Fitting: (see C diagrams) The conditioner comes supplied with a metallic mounting frame which simpli es the process of drilling air entry and exit holes. It also has extendable ducting to be cut to length (75 cm each) in order to install the conditioner whatever the thickness of the wall.
  • Page 12 - Where the grids were located, position and screw, using a Hex wrench (supplied) the 2 anges* onto the housing (1) and (2). - Fit together the reducer* (3). - Position the air extraction piping (standard piping, 160 mm in diameter, not supplied). *Consult your EuroCave distributor (13) (14)
  • Page 13: Iv- Discharging Condensate

    - Position the air extraction piping (standard piping, 160 mm in diameter, not supplied) (2) (3). For this type of fitting, it is necessary to ensure sealing around the piping. *Consult your EuroCave distributor IV- Discharging condensate The conditioner was designed to allow condensate to be discharged (discharge pipe located under the conditioner’s housing) either inside the cellar, if the humidity level is too low, or outside the cellar.
  • Page 14: Conditioner Operation

    8 - C ONDITIONER OPERATION T he IN OA conditioner is tted with a refrigerating unit: • an evaporator forces cold air inside the room, • a condenser expels the hot air outside. The evaporator fan operates continuously to ensure that air is constantly mixed and that temperatures are as uniform as possible,in accordance with speeds automatically adjusted according to requirements.
  • Page 15: Installing The Remote Control

    9 - I NSTALLING THE REMOTE CONTROL I- Remote control description Radio frequency remote control (433.92 Mhz) Each remote control has a personalised code matched to the conditioner. Power supply: 2 x 3V (CR 2430 battery, supplied) Low battery indicator Temperature indicator Knob...
  • Page 16: Iii- Installing The Remote Control Outside The Cellar

    9 - I NSTALLING THE REMOTE CONTROL III- Installing the remote control outside the cellar The remote control can also be placed outside the cellar. In this case, it is essential to connect a sensor (supplied with the appliance) to the remote control before installing it. a- Connecting the sensor to the remote control - On the back of the remote control, push the 2 batteries downwards using a screwdriver (see diagram below).
  • Page 17 9 - I NSTALLING THE REMOTE CONTROL - Programming the remote control Where placing the remote control outside the cellar, having connected the external sensor, it is essential to reprogramme the uni t - To turn on the remote control, press and hold down the key for about 8 seconds until the indicator goes o .
  • Page 18: Commissioning Your Conditioner

    10 - C OMMISSIONING YOUR CONDITIONER I- C onnection C heck that the plug is connected to a power supply (presence of correct amp fuses, functioning 30 mA* di erential circuit breaker - not applicable to certain countries).W ait 48 hours before plugging in your conditioner. II- Switching on - Place the switch, located under the conditioner, in position 1.
  • Page 19: Iv- Installing The Remote Control

    10 - C OMMISSIONING YOUR CONDITIONER IV- Installing the remote control You can install the remote control inside your cellar. W e recommend that you place it as close as possible to the bottles. Fix the unit close to your bottles using the supplied pegs and screws (see diagram below) N .B.: Do not place the remote control in the path of the conditioner’s cold air ow.
  • Page 20: Commissioning Your Conditioner

    10 - C OMMISSIONING YOUR CONDITIONER - Press the key to con rm the new setting, the display then returns to the new setting. T he setting can be adjusted between 9 and 15°C . Beyond this range, the keys do not work. WARNING: to operate correctly, your conditioner must be in a location where the ambient temperature is between -5°C is 35°C.
  • Page 21: Maintenance

    11 - M AINTENANCE It is necessary to thoroughly clean the conditioner’s internal elements every year. - Unplug the appliance. - Place the appliance on the ground to disassemble it (4 screws). - Vacuum the 4 air entry and exit grids. - Remove the upper cover (2 screws) (1).
  • Page 22 The information in this document is subject to modi cation without prior notice. EuroCave o ers no guarantee on this equipment item if it is used for any speci c purpose other than that for which it was des igned. EuroCave cannot be held responsible for any errors in this manual, nor for any damage linked to or following the provision, performance or use of the equipment item.
  • Page 23 Around Wine 57 Chiltern Street London W1U 6ND 020 7935 4679 eurocave@aroundwine.co.uk www.eurocave.co.uk - eurocave@aroundwine.co.uk...

This manual is also suitable for:

Inoa 50

Table of Contents

Save PDF