Electrical Requirelnents; Complete The Safety Reversing Sensor Installation - Craftsman 139.53663SRT Owner's Manual

1/2 hp
Hide thumbs Also See for 139.53663SRT:
Table of Contents

Advertisement

Installation Step 8
Electrical
Requirements
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third grounding
pin. This plug will only fit into a grounding type outlet.
If the plug doesn't fit into the outlet you have, contact a
qualified electrician to install the proper outlet.
I
To avoid installation difficulties,
do not run the opener until Step 9 below.
If permanent
wiring is required
by your local code,
refer to the following procedure:
I
To preventelectrocutionor fire, installationand wiring
mustbe in compliancewith localelectricaland building
codes,
Do NOT usean extensioncord,2-wireadapter,or change
the plugin any wayto makeit fit youroutlet,
RighO
Permanent Wiring
Connection
To make a perlnanent connection through the 7/8" diam.
hole in the top of the opener (according to local code):
• Remove the opener cover screws and set the cover aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire m the screw on the brass
terminal; the white (neutral) wire to the screw on the
silver terminal; and the ground wire to the green
ground
screw.
The opener must be grounded.
• Reinstall the cover.
Ground Tab
Green
Ground Screw
Ground
White Wire
BIackWire
Installation Step 9
Complete
Safety Reversing
Sensor
Installation
Aligning the Safety Sensors
• Plug in the opener. Green indicator lights in both the
sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.
The sending eye indicator light will glow regardless of
alignment or obstruction. If the indicator light is of£ dim,
or flickering in the lvceiving c3,e (and the invisible light
beam path is not obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust, aiming
directly at the receiving eye. Lock in place.
• Loosen the receiving eye wing nut and adjust sensor
vertically and/or horizontally
until it receives the
sender's beam. When the green indicator light glows
steadily, tighten the wing nut.
22
Trouble Shooting
1. If the sending eye indicator light does not glow
steadily after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These can
occur under staples or at screw terminal connections.
• Incorrect wiring between sensors and opener.
• An open wire (wire break).
2. If the sending eye indicator light glows steadily but the
receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
3. If the receiving eye indicator light is dim, realign
either sensor.
NOTE:
When the itwisible beam path is' obstructed or
re#aligned
while the door is' closing, the door will
revels'e. If the door is' already open, it will not close. The
opener li@ts will flash 10 times. (If bulbs my not
installed, 10 clicks' are audibleJ Seepage
16.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents